background image

w w w . a e r m e c . c o m

T r a n s l a t i o n   f r o m   o r i g i n a l

U s e r   m a n u a l

EN

 

WIRED PANEL

2 0 . 1 1   -   5 3 8 5 4 8 3 _ 0 0

W R C 4 0

Summary of Contents for WRC40

Page 1: ...w w w a e r m e c c o m T r a n s l a t i o n f r o m o r i g i n a l U s e r m a n u a l EN WIRED PANEL 2 0 1 1 5 3 8 5 4 8 3 _ 0 0 W R C 4 0...

Page 2: ......

Page 3: ...TIMED PROGRAMMING 19 DAILY TIMER DAILY TIMER PROGRAMMING 20 WEEKLY TIMER WEEKLY TIMER PROGRAMMING 21 TWO WEEK TIMER FORTNIGHTLY TIMED PROGRAMMING 22 COUNTDOWN TIMER ON 23 COUNTDOWN TIMER OFF 23 SET C...

Page 4: ...for any notice thereof Thank you once again AERMEC S p A This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the...

Page 5: ...dify or repair the air conditioner by yourself 5 Do not move or re install the device by yourself 6 Do not use flammable materials near the device To clean the device do not use organic solvents such...

Page 6: ...again automatically after a power failure The user interface has an LCD display with simple icons giving information and showing the available functions on the units the user can interact with the pan...

Page 7: ...7 INSTALLING THE WIRED PANEL DIMENSIONS OF THE WIRED PANEL 112 112 22 106 5 48 106 5 30 30 24 mm...

Page 8: ...s the serial communication cable through the specific trunking as far as the flush mounting box 3 Fix the panel to the flush mounting box using the screws supplied WARNING To avoid electromagnetic dis...

Page 9: ...itch the indoor unit on or off or to return to the previous level when scrolling through the menus 5 Sets the operating mode for the unit 6 Used to activate or deactivate a function or to move from on...

Page 10: ...ndicates the current fan speed setting Indicates that the settings are saved on the wired panel memory The energy saving function is active The prolonged ventilation function is active X FAN The air f...

Page 11: ...nt cannot be altered but ventilation and other functions such as swing can be set as normal WARNING this mode cannot be selected if the SAVE function is active Cooling this mode cools the ambient air...

Page 12: ...increase the operating setting by 1 C A long press will increase or decrease the value by 1 C every 0 3 seconds Press the button MENU OK FAN ON OFF MODE SWING to modify the fan speed In the DRY mode o...

Page 13: ...the set position the logic where this function is managed When the unit is on while pressing the button it s possible to set one by one the following steps SWING disabled SWING disabled If the unit is...

Page 14: ...deactivate the functions press the MENU OK FAN ON OFF MODE SWING or MENU OK FAN ON OFF MODE SWING button If the selected function offers this option press MENU OK FAN ON OFF MODE SWING to access the...

Page 15: ...nd dehumidifica tion modes and a maximum temperature limit for heating mode This allows the unit to work within a temperature range that guarantees energy savings After selecting the SAVE function use...

Page 16: ...ff to ensure that the predefined working set point is reached After entering the sub menu of the SETBACK function use the MENU OK FAN ON OFF MODE SWING or MENU OK FAN ON OFF MODE SWING button to selec...

Page 17: ...ating position During this process the message RESET WINDOW will appear on the control panel the HOME page will be automatically restored when the operation has ended CONTROLLING THE OPENING OF THE FR...

Page 18: ...n and then press MENU OK FAN ON OFF MODE SWING to access the required menu Use the MENU OK FAN ON OFF MODE SWING or MENU OK FAN ON OFF MODE SWING button to select the item you want to see then press M...

Page 19: ...mmed TIMER OFF switch off programmed To quit the sub menu and return to the previous levels press MENU OK FAN ON OFF MODE SWING ONCE TIMER SINGLE TIMED PROGRAMMING With single timed programming the un...

Page 20: ...ndicates the time when the selected action must be implemented OnOFF indicates the command ON activates the unit OFF deactivates it associated with the selected action COOL indicates the cooling setti...

Page 21: ...e next row The values to be set for this function are SCH indicates the number and the status ON ac tive OFF not active of the selected action TIME indicates the time when the selected action must be...

Page 22: ...e right has been reached the cursor will automatically move onto the next line The values to be set for this function are SCH indicates the number and status ON active OFF not active of the selected a...

Page 23: ...N OFF MODE SWING button to set the required value for the selected number the value being defined is shown in black Press MENU OK FAN ON OFF MODE SWING to save the settings To quit the sub menu and re...

Page 24: ...m The available items are CLOCK FORMAT to set the format for viewing the time on the panel display 12 or 24 hour CLOCK to set the time and date Use the MENU OK FAN ON OFF MODE SWING or MENU OK FAN ON...

Page 25: ...he wired panel MODE activates or deactivates the lock on the choice of operating mode via the wired panel SET TEMPERATURE activates or deactivates the lock on the modification of the operating setting...

Page 26: ...DE SWING or MENU OK FAN ON OFF MODE SWING key two parameters Address mode the type of centraliser connected to the system this parameter MUST BE SET WITH A VALUE OF 01 Remote control address the seria...

Page 27: ...e used by technical assistance personnel To set this function select the Select the ambient temperature label using the MENU OK FAN ON OFF MODE SWING or MENU OK FAN ON OFF MODE SWING key then use MENU...

Page 28: ...he required value 1 logic 1 In cooling mode the indoor unit keeps the ventilation active even when the operating set point has been reached whereas in heating mode DUCT TYPE and FLOOR CEILING units ke...

Page 29: ...he compressor is limited to avoid damage to the unit FH In excessively low ambient temperature conditions the working frequency of the compressor is limited to avoid damage to the unit PH Error on con...

Page 30: ...30...

Page 31: ...31...

Page 32: ...4 4 2 6 3 3 1 1 1 F a x 3 9 0 4 4 2 9 3 5 7 7 s a l e s a e r m e c c o m w w w a e r m e c c o m SCARICA L ULTIMA VERSIONE DOWNLOAD THE LATEST VERSION T L CHARGER LA DERNI RE VERSION http www aermec...

Reviews: