background image

5389551_01 - 1601

USER MANUAL

EN

WLRC

Summary of Contents for INVERTER WLRC

Page 1: ...5389551_01 1601 USER MANUAL EN WLRC ...

Page 2: ...Although every effort has been made to ensure accuracy Aermec shall not be held liable for any errors or omissions This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled disposal of Waste Electrical and Electronic Equipment WEEE please return the device using appropr...

Page 3: ...value operating setpoint timer etc 3 Decreases value operating setpoint timer etc 4 Activates or deactivates the maximum fan speed TURBO 5 Sets the fan speed 6 Operating mode selection 7 Sets the operation of the motorised air discharge fin swing function 8 Not used 9 Activates or deactivates the function iFeel 10 Activates deactivates or changes the programmed switch on timer 11 Activates deactiv...

Page 4: ... unit of measurement for the tempera ture setpoints C or F 12 Indicates that the figures displayed next to the icon represent the current system time 13 Indicates if a timer is set for starting 14 Indicates if a timer is set for switching off 15 Indicates the state of the SWING function 16 Indicates the operating setpoint temperature in the various modes 17 Indicates the extended ventilation funct...

Page 5: ... in this mode no setpoint value is dis played on the remote control and the fan speed setting is AUTO COOLING mode in this mode the user must set the oper ating setpoint and a fan speed If the room air tempera ture is higher than the setpoint the unit is switched on until the room temperature drops below the setpoint value DEHUMIDIFICATION mode in this mode the user must set the operating setpoint...

Page 6: ... setpoint 2 4 SETTING THE FAN SPEED Pressing the F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP button If the unit is on and the automatic or dehumidification modes are not selected allows the selec tion of the fan speed Pressing the button allows changing the fan speeds as shown in the icons below in the following sequence Setting the fan speed AUTO Minimum Averaged Ma...

Page 7: ...These units are equipped with an internal clock which can display the current time by pressing on the F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP key the clock icon will start to flash this flashing will last 5 seconds after this if no key is pressed you automatically exit the time modification mode while the clock icon is flashing it is possible to change the system...

Page 8: ...ill be the same as those present when the unit stops 2 8 SETTING OR CANCELLING A PROGRAMMED SWITCH OFF TIMER OFF The units possess a timer used to program switching off by specifying the time that you want the unit to deactivate If the unit is switched off and no other programmed switch off times are present by pressing the F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP...

Page 9: ...EP key the function will be deactivated however to be activated again the unit needs to be on 2 10 DISPLAYING THE ROOM TEMPERATURE OR THE OPERATING SETPOINT ON THE INDOOR UNIT DISPLAY Through the use of the remote control it is possible to display the room temperature value read by the indoor unit or dis play the current operating setpoint used by the unit This infor mation is displayed on board t...

Page 10: ...plied In cooling or dehumidification the temperature setpoint is gradually increased to guarantee maximum comfort combined with energy saving In heating the temperature setpoint is gradually de creased to guarantee maximum comfort combined with energy saving If the unit is on except in automatic or ventilation mode pressing the F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN S...

Page 11: ...ower is on and the cooling mode is selected simulta neously pressing the keys F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP plus F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP will toggle the energy saving function If the function is active on the remote screen icon appears F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN...

Page 12: ...te the antifreeze function the function will be disabled automatically Nightmode Set the frost protection F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP 2 16 SET THE FUNCTION IFEEL The user holding the remote close can precisely control the climate around him Press the button F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP to activate the IFEE...

Page 13: ...ON OFF MODE FEEL T ON T OFF TEMP CLOCK GHT X FAN SLEEP icon on the remote control s display shows that the key pad of the remote control is locked Setting the button lock 2 18 SETTING THE UNIT OF MEASUREMENT With the machine off pressing the buttons F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP and F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SL...

Page 14: ...WRC will appear briefly acronym UC and it will appear in a fixed marked MASTER panel display flush WRC NOTE Systems MVA can be only one MASTER so each new set ting of a master unit remove any old master Set master unit F A N T U R B O ON OFF MODE I FEEL T ON T OFF TEMP CLOCK LIGHT X FAN SLEEP 2 20 REPLACING THE REMOTE CONTROL S BATTERIES To replace the batteries of the infra red remote control pro...

Page 15: ......

Page 16: ...sponsabilité pour les erreurs ou omissions éventuelles All specifications are subject to change without prior notice Although every effort has been made to ensure accuracy Aermec does not assume responsibility or liability for eventual errors or omissions Alle specificaties kunnen zonder voorafgaande kennisgeving worden gewijzigd Hoewel alle moeite is gedaan om de nauwkeurigheid te garanderen heef...

Reviews: