background image

Instruction Manual

 Receiver suply voltatge

12/24 AC/DC

 Transmitter suply voltatge

2x lithium battery 3V DC type CR2032

 Receiver memory

14 transmitters

 Receiver Output

Relay,micro disconnection 1B

 Receiver Power consumption

Ball pressure test (IEC 695-10-2)

PCB (125ºC) WRAP (75ºC)

Pollution degree

2

Protection class (IEC 60529)

Ip67

Frecuency Channels

 Range
 Working temperature
 Software
 Rated transient over voltage
 Transmitter power consumption

0.5 W - 12 V / 1,2 W - 24 V

868.95MHz & 869.85MHz
100m
-35ºC to +55ºC
Class A
330V
Transmitting 17mA / stand by 16uA

Machine Security Normative 

                    EN 13849-2:2008 PL-C 

Category 2

TECHNICAL SPECIFICATIONS

GENERAL (TRANSMITTER) 

START-UP 

TRANSMITTER OPTION SELECTOR 

RECEIVER 

Radio transmission system for resistive safety edges. The system consists of a transmitter unit and a receiver unit.

Important:

- Insert battery 1 first and then battery 2! Unless this order is observed, correct function is not guaranteed. The batteries must be suitable for use at 
temperatures of -20°C and above
- The system has no fuse protection. It is advisable to include a fuse protection of minimum 100mA and maximum 250mA into the external Power.

1- Terminals
2- Battery1 CR2032
3- Battery 2 CR2032
4- LED
5- DIP - Switch
6- Push button
7- Antenna

1- Terminals
2- LED 1
3- Push button
4- DIP - Switch
5- LED 2
6- Buzzer
7- Antenna

WirelessBand transmitter and  receiver must be mounted on separate surfaces.

1.- Insert the enclosed batteries into the transmitter (type CR2032). Important: insert battery 1 first and then battery 2! Unless this order is observed, 
correct function is not guaranteed.
2.- Connect receiver to supply voltage. (Note correct polarity for DC.)
3.- Check switch settings.
4.- Carry out programming steps. Transmitter and receiver are now matched to one another.
5.- Install transmitter on gate. 
6.- Wire safety edge to transmitter.
7.- Install receiver at designated location.
8.- Wire supply voltage, test input and output to control unit.
9.- Switch on voltage.
10.- Carry out test by actuating the connected safety edge in different gate positions, particularly the open and closed positions.
11.- We recommend carrying out steps 1 to 4 prior to installing the device. A minimum distance of 1m must be observed between the transmitter and 
  Receiver.

OPTION 1 - SAFETY EDGE TYPE 

ON

Resistive safety edge

OFF

Contact safety edge

OPTION 2 - TRANSMITTER FRECUENCY

ON

Frequency 869,85 MHz, setting MUST match that of receiver

OFF

Frequency 868,95 MHz, setting MUST match that of receiver

1

5

2

3

4

6

7

1

2

3

5

4

6

7

TRANSMITTER 

TRANSMITTER 

GB

( WIRELESSBAND 1.0 )

Reviews: