MFC Series Boilers User Manual
CHAPTER 8 – MFC 4000/6000 DUAL FUEL BURNER
P
OMM-0104_94
AERCO International, Inc.
•
100 Oritani Dr.
•
Blauvelt, NY 10913
Page
85
of
170
GF-146
Ph.: 800-526-0288
12/29/2015
Startup for MFC 4000 – 6000 Dual Fuel Burner
8.15.1
Starting the Burner
1. Turn on electricity to the burner by turning the power switch on the boiler panel to ON.
2. Close the thermostats/pressure switches and set the parameters on the RWF 40 regulator.
Please refer to the appropriate manual for instructions to perform this operation.
3. Turn the switch shown on Figure 8-22 to the
“ON”
position and turn the switch of to position
“LOCAL”
and turn the switch to position “
OIL
” for oil operation and “
GAS
” for gas operation.
Figure 8-22: Burner Controls Used for Startup
DANGER!
Make sure that the lamps or testers connected to the solenoids, or indicator lights on the
solenoids themselves, show that no voltage is present. If voltage is present, stop the burner
immediately
and check the electrical wiring.
NOTE:
For the start-up procedure and the parameters calibration, refer to the specific instruction
manual of the LMV37 electronic cam supplied with the burner.
DIRECTION
OF MOTOR
ROTATION