Aeotec MultiSensor Installation Instructions Download Page 1

MultiSensor

(Z-Wave 4-in-1 Sensor: 

Motion, Temperature, Humidity, and Light Sensor)

Introduction:

Important Disclaimer:

The Aeotec MultiSensor is a USB or battery-powered 

Z-Wave motion sensor, temperature sensor, humidity 

sensor, and lighting sensor all in one package. The 

sensor will send radio signals to up to 6 associated 

Z-Wave devices within its own Z-Wave network when 

the Motion Sensor detects IR changes in front of its 

viewing window.

Indoor/Outdoor functional tolerances allow the Aeotec 

MultiSensor to function under weatherized conditions. 

Various sensitivity levels can be configured to avoid 

unintentional triggering from small animals such as cats 

and dogs.

By taking advantage of the Z-Wave mesh network, 

commands can be routed to their destination via 

intermediary “listening” Z-Wave products.  Products that 

are Z-Wave certified can be used and communicate with 

other Z-Wave certified devices.

This product uses radio to wirelessly communicate 

data between itself and other devices. Radio 

communication is inherently not always 100% 

reliable, and as such, this product should not be 

used in situations in which life and/or valuables are 

solely dependent on its function.

 

· MultiSensor Physical Instructions:

There are 2 methods to physically mount the MultiSensor on the 

wall or ceiling.  It can be mounted flat against the wall via the 

Back-Mount Plate or angled in a direction via the Back-Mount Arm.

Important: The MultiSensor is weatherized and can operate 

outdoors in rain and snow.  Placed outdoors where directly exposed 

to rain and snow, the MultiSensor should be oriented such that the 

Temperature/Humidity Sensor is facing downward and positioned 

on the bottom of the unit. (See the Weatherization Orientation 

section.)

Recommendation:

 For networks which do not have a method to 

display the battery level of the Aeotec MultiSensor, it is 

recommended that the sensor be tested occasionally to ensure 

that the battery still hold enough charge to operate. Batteries 

naturally lose their charge over time. 

Note: The Back-Mount Arm may be locked in various angles by 

turning the Friction Lock clockwise and counter-clockwise to 

tighten or loosen (respectively) the angle of the arm.

Recommendation: 

For best performance, the MultiSensor should 

NOT be mounted directly on or near metal framing or other large 

metallic objects. Large metal objects may weaken the radio signal 

transmitted.

1

Mounting the MultiSensor flat against the wall via the 

Back-Mount   Plate.

2

Mounting the MultiSensor angled in a direction via the 

Back-Mount Arm.  

2

Insert 4 AAA batteries oriented 

according to the picture located 

in the battery holder (with the 

negative end depressing the 

battery spring). 

3

Lock the MultiSensor main unit to its battery cover by aligning 

the Lock/Unlock Half-Dimple Markers under the “unlock” 

symbol and twisting the battery cover from the main unit in a 

clockwise motion until the Lock/Unlock Half-Dimple Markers 

form a circle under the “lock” symbol (a tangible click will be 

felt).

The Aeotec MultiSensor has built in battery level detection. It will 

automatically report its battery level to the associated gateway 

throughout its life until the battery is fully drained and needs 

replacing. The battery status will often be displayed in the user 

interface of the gateway.

When used properly in an optimized Z-Wave network, operation via 

battery can function for 12 months before battery replacement.

1

Unlock the MultiSensor from it’s battery cover by twisting the 

battery cover from the main unit in a counter-clockwise motion 

and pulling the battery cover outward to separate the main unit 

from the battery cover. 

Main Unit

Battery Cover

Unlocked

Main Unit

Battery Cover

Locked

This Side

UP

OPEN

CLOSE

Sensitivity Knob

Battery Holder

USB Power Port

Z-Wave Button

Back Mount Hook

Back Mount Plate

Back Mount Arm

Friction Lock

Temperature/

Humidity Sensor

Motion Sensing

 Window

Lock/Unlock 

Half-Dimple

Markers

LED

Back Mount Plate

Ceiling

Back Mount Plate

Back Mount Arm

Tighten/Loosen

Friction Lock

CORRECT

WRONG

Water can enter

humidity sensor

Technical Specs

Package Contents:

1) MultiSensor

2) Back-Mount Plate

3) Back-Mount Arm

4) AAA Batteries (x4)

5) USB Cable

6) Screws (x2)

2

3

6

5

4

1

Sensitivity

AAA

AAA

AAA

AAA

10 meters

3 meters

Celling

 

· MultiSensor Power Instructions:

· Adjusting the Sensitivity on the MultiSensor

Turn the Sensitivity Knob in a clockwise direction to increase 

sensitivity and counter-clockwise to decrease sensitivity. 

 

· Motion Sensor Effective Range:

 · MultiSensor Physical Installation Instructions:

 

· Weatherization Orientation:

Sensitivity Knob

Sensitivity

AAA

AAA

AAA

AAA

1

2

Ground

Wall

2.5 meters

Ground

3.5 meters

120

°

5 meters

0.5 meter

6 meters

Reviews: