 This device is a Z-Wave Remote Control.

Use Network Management Buttons to include and exclude devices to the remote controls network and use the LEARN button to
include the minimote into a different network. Pushing the LEARN button for 5 sec will wake up the device.
Please refer to the chapters below for detailed information about all aspects of the products usage.

Product description

The Aeon Labs mini remote control can control a variety of Z-Wave compatible devices such as switches, dimmers, window blinds
and motion sensors. The device can include and exclude devices, group them and set and release associations. The mini remote
only offers four control buttons for scene selection. Behind a slider there are four more buttons for Z-Wave network control. A non-
replaceable but rechargeable battery powers the remote control. Recharging is done on a conventional USB bus using the charging
cable provided. The product is in the color black.

Installation Guidelines

The device is ready for use. In case there are no LED signals when hitting the buttons the device needs to be recharged using the
USB cable provided.

Summary of Contents for Minimote

Page 1: ...ct description The Aeon Labs mini remote control can control a variety of Z Wave compatible devices such as switches dimmers window blinds and motion sensors The device can include and exclude devices...

Page 2: ...unicate with the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep...

Page 3: ...unication between two Z Wave devices only works if both belong to the same wireless network Joining a network is called inclusion and is initiated by a controller The controller needs to be turned int...

Page 4: ...vices and it will result in an update of the network information in the battery operated controller This prevents wrong communication that may cost battery life and delay other communication Press the...

Page 5: ...wer left Parameter Number 243 Parameter Size 1 Defines the switching mode of Button 3 Value Description 0 Factory Default Default 1 Scene Mode 2 Add Mode 3 Remove Mode 4 Association Mode 5 Learn Mode...

Page 6: ...0 Factory Default Default 1 Scene Mode 2 Add Mode 3 Remove Mode 4 Association Mode 5 Learn Mode Mode of Button 7 marked as Association Parameter Number 247 Parameter Size 1 Defines the switching mode...

Page 7: ...thal Germany www zwaveeurope com 5 Learn Mode Technical Data Explorer Frame Support Yes SDK 4 50 beta Device Type Slave with routing capabilities Generic Device Class Binary Switch Specific Device Cla...