1. OVERVIEW 

1)

 

The brushless water pump is designed for indoor or outdoor fountain or water pond use, and is powered by a DC 
power source such as solar module, rechargeable battery or AC/DC adapter etc. 

2)

 

While using solar module as the power source, performance of the pump will depend on sunlight intensity and the 
incident angle at which sunlight strikes the panel surface. 

3)

 

The  pump  was  designed  for  high  efficiency,  long  lasting  continues  operation with  the  latest  DC  brushless  motor 
technology. 

 
2. COMPONENTS 
 

                       

3. ASSEMBLING                                                             

1)

 

Unpack all components carefully.   

2)

 

For the application of producing a waterfall feature, fit the pump outlet to the water inlet of the decoration. 

3)

 

For the application of creating a small spraying up fountain, please follow the steps below: 
a)

 

Fit the nozzle onto the top of the pump tube, the nozzles can produce 2 different jet shapes. 

b)

 

Fix the pump at the base of a basin or bottom of a small shallow pond etc. 

c)

 

It is best to keep the pump off the pond base to avoid drawing the pond waste into the pump, which will lead 
to blockage in the pump. Use a brick or similar to elevate the pump. 

d)

 

To  produce  excellent  fountain  effect,  please  leave  the  fountain  head  above  the  water  surface  by  using  the 
extension tubes. If these 4pcs of extension tubes are all used and the pump head is still immerged in water, 
please uplift the pump body from below. 

4)

 

Connect the pump to a proper DC power supply with an output voltage between 12V to 24V. 

5)

 

Make sure to keep the pump fully submerged while the pump is operating.   

6)

 

The pump is now ready to operate. 

 

4. CAUTIONS 

1)

 

Any altering of the product itself or changing of the components voids warranty. 

2)

 

Do not connect the pump to any AC power supply directly; it’s designed ONLY for DC power.   

3)

 

All the connectors are protected against reverse polarity as shown in the right figure. Do not insert the plug with 
reverse polarity by using unnecessary force. 
 
 
 
 

 

4)

 

Operate the pump in water only (never above 100°F), especially keep it away from flammable liquids. 

5)

 

Do not let the pump run dry. 

 