background image

16

 

RMS Clamp-on Simple Logger® Model CL600

Limited Warranty

The  Simple  Logger

®

  CL600  is  warranted  to  the  owner  for  a  period  of 

two

 

year

s

 from the date of original purchase against defects in manufacture. This 

limited warranty is given by AEMC

®

 Instruments, not by the distributor from 

whom it was purchased. This warranty is void if the unit has been tampered 

with, abused or if the defect is related to service not performed by AEMC

®

 

Instruments. 

For  full  and  detailed  warranty  coverage,  please  read  the  Warranty 

Coverage  Information,  which  is  attached  to  the  Warranty Registration 

Card  (if  enclosed)  or  is  available  at  www.aemc.com.  Please  keep  the 

Warranty Coverage Information with your records.
What AEMC

®

 Instruments will do:

If  a  malfunction  occurs  within  the 

warranty

 period,  you  may  return  the  in

-

strument  to  us  for  repair,  provided  we  have  your  warranty  registration 

in

-

formation  on  file  or  a  proof  of  purchase.  AEMC

®

 Instruments  will,  at  its 

option, repair or replace the faulty material.

REGISTER ONLINE AT:

www.aemc.com

Warranty Repairs

What you must do to return an Instrument for Warranty Repair: 

First,  request  a  Customer  Service Authorization  Number  (CSA#)  by  phone 

or by fax from our Service Department (see address below), then return the 

instrument along with the signed CSA Form. Please write the CSA# on the 

outside of the shipping container. Return the instrument, postage or shipment 

pre-paid to:

Ship To:

  Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments

15 Faraday Drive • Dover, NH 03820 USA

Phone: (800) 945-2362  (Ext. 360)

(603) 749-6434  (Ext. 360)

Fax:  (603) 742-2346 or (603) 749-6309

E-mail: [email protected]

Caution:

 To protect yourself against in-transit loss, we recommend you insure 

your returned material.

NOTE: You must obtain a CSA# before returning any instrument.

Summary of Contents for Simple Logger CL600

Page 1: ...SIMPLE LOGGER RMS CLAMP ON MODULE CL600 E N G L I S H User Manual...

Page 2: ...rument Please record this number and purchase date for your records RMS CURRENT CLAMP ON SIMPLE LOGGER MODEL CL600 CATALOG 2116 11 SERIAL _ _______________________________________________ PURCHASE DAT...

Page 3: ...ical Specifications 7 3 3 Environmental Specifications 7 3 4 Safety Specifications 7 4 OPERATION 8 4 1 Software Installation 8 4 1 Recording Data 9 4 3 Using the Software 10 5 MAINTENANCE 11 5 1 Batte...

Page 4: ...ument while connected to any circuit or input ALWAYS inspect the instrument and lead prior to use Replace any defective parts immediately NEVER use the Model CL600 on electrical conductors rated above...

Page 5: ...er and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim Do not use an instrument that appears to be damaged 1 3...

Page 6: ...S 232 Interface PRESS RS 232 LOGGER OPERATION 1 Press to Start Logging Logging Two Blinks 2 Press to Stop Logging Stand By One Blink 3 Press Hold 5 Seconds to Shut Off Off No Blinks Warning All Data w...

Page 7: ...D indicates the status of the logger Single Blink STAND BY mode Double Blink RECORD mode Continuously On OVERLOAD condition No Blinks OFF mode Warning Delete Data Pressing the PRESS button for more th...

Page 8: ...0 to 600A Resolution 8 Bit 0 5Arms Scale Range Maximum Input Resolution 100 600 Arms 4 Arms 50 500 Arms 2 Arms 25 250 Arms 1 Arms 12 5 125 Arms 0 5 Arms Sample Rate 4096 hr max decreases by 50 each ti...

Page 9: ...42mm 2 conductors 1 25 4mm each Case Material Polycarbonate UL V0 3 3 Environmental Specifications Operating Temperature 4 to 158 F 20 to 70 C Storage Temperature 4 to 176 F 20 to 80 C Relative Humidi...

Page 10: ...ored file One 9 pin serial port one parallel port for printer support CD ROM drive 1 Insert the Simple Logger CD into your CD ROM drive If auto run is enabled the Setup program will start automaticall...

Page 11: ...low the on screen prompts to install the software 4 1 Recording Data Position the Model CL600 around the conductor to be measured NOTE Be sure that the positioning of the CL600 allows the jaws to firm...

Page 12: ...ched you will need to select a language Select Port from the menu bar and select the Com port COM 1 2 3 or 4 you will be using see your computer manual Once the software automati cally detects the bau...

Page 13: ...ed screw 3 Locate the two wire red black battery connector and attach the 9V battery to it Make sure that you observe polarity by lining up the battery posts to the proper terminals on the connector 4...

Page 14: ...click on the desired file to open the Text Import Wizard 5 Review the selections in the first wizard screen and make sure that the following choices are selected Original Data Type Delimited Start Im...

Page 15: ...ick on column B at the top of the column to select the data then click on Insert from the main menu and select Columns from the drop down menu 2 Next click on column A at the top of the column to sele...

Page 16: ...e option from the category list on the left Select the time format you desire and click on OK to format the column Figure A 2 shows a typical spreadsheet with date time and value displayed It may be n...

Page 17: ...Includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 F...

Page 18: ...you may return the in strument to us for repair provided we have your warranty registration in formation on file or a proof of purchase AEMC Instruments will at its option repair or replace the fault...

Page 19: ......

Page 20: ...08 18 99 MAN 100215 v13 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...

Reviews: