4
2 - DESCRIPTION
LIQUID CRYSTAL DISPLAY
Q
2000 measurement counts (height of digits 0.65")
Rate : 2 measurements / second
Q
: low battery indication
Q
Overload indication : the 1 on the left flashes
CONTROL BUTTONS
HOLD
Hold button freezes the measurement on display
RANGE
Range selection : Press the range button to change from automatic
mode to manual mode. The automatic mode is selected when the
instrument is switched on.
Note :
The 200 mV AC range is only accessible on manual.
Press 3 times on the RANGE button to access this range.
FUNCTION SELECTOR SWITCH
OFF
Off position
V
DC and AC voltages up to 600 V
Continuity sound test for a resistance R < 700
Ω
Ω
Ω
Ω
Ω
Ω
Resistances up to 20 M
Ω
.
TERMINALS
Ø 4 mm safety terminals
Q
COM
: common, black
Q
+
: red
3 - DC AND AC VOLTAGE
Q
Connect the leads to the multimeter and connect it in parallel to
the circuit to be tested.
Q
Place the selector switch on the voltmeter function V. Automatic
selection of the range and the DC or AC mode; read the value
measured.
Q
Freeze the value, if necessary, by pressing the HOLD button.