20
3.2.1. NMEA-Sensors
Using NMEA-sensors, the telegrams [IN] can be chosen which the met[LOG] reception shall evaluate.
Available for selection:
•
WIMWV
•
WIMTA
•
WIMMB
•
WIMHU
•
WIXDR (PR)
•
WIXDR (C/H/P)
(For a detailed description of the telegrams please also see chapter 9.1).
Alternatively, a result output of a true wind calculation (NMEA TW [OUT]) can be issued via a COM-
interface
3.2.2. Talker protocol of the rain[e]
Having chosen the COM-interface of the rain[e]-talker, following measuring values for further configu-
rations of the visualisation and the data storage are available:
•
The intensity in mm/min
•
The total amount in mm (amount of precipitation each storage interval)
•
The heating status
•
Internal temperature in °C
•
The system status
The total amount indicates the collected precipitation in mm since the device has been switched on.
From the total amount, the met[LOG] calculates the amount of precipitation (in mm) for each storage
interval.
3.2.3. Configuration of the rain[e] SDI-12 on RS485
If the measured values of the rain[e] are collected via the SDI-12 protocol on RS485, data call interval
can be set up via the met[LOG].
Measured values are collected every 10 seconds (at standard configuration).
Available selection:
•
Intensity of precipitation last minute in mm/min
•
Amount of precipitation since last call mm/m²
•
Internal temperature °C
•
Heating ON (1) / OFF (0)
•
Total heating capacity %
•
All error states:
o
Error code for LAMBRECHT-service
0...99
o
Error exceeding of 10° C at heating ON
0 or 1
o
Error heating
0 or 1
o
Error temperature sensor interior space
0 or 1
o
Error temperature sensor at the funnel
0 or 1
o
Just for LAMBRECHT-Service 4
0 or 1
o
Just for LAMBRECHT-Service 5
0 or 1
o
Just for LAMBRECHT-Service 6
0 or 1
o
Just for LAMBRECHT-Service 7
0 or 1