89
Scalars Operation
The scalar sensor applies a gain (if specified) to the input
which is then multiplied by the scalar and the offset
added. If signed is ticked and the gain is not set to
NONE, the input is treated as a twos compliment
number. The scalar sensor is used for linear signals.
Functions Operation
The function table sensor is used when a non-linear signal needs to be processed. The function table sensor applies
a gain (if specified) to the input and looks up the input in the function table to produce the appropriate output. If the
input falls between two values, linear interpolation is used to derive the output value unless the Interpolate Between
Input Values check box is unchecked.