--------------------------------------------------------------------------------21/45--------------------------------------------------------------------------------
…
Note: The function VS shows just the settings that are used in the actual ISO standard.
1
just available in the ISO 14443A standard
2
just available in the ISO 15693 standard
3.4
General reading instructions
3.4.1
GA – get active
The command GA causes one reading cycle. There are different cycles for different transpondertypes.
This command is only available in the ISO 14443A standard.
Mifare 4 byte UID:
request (REQA)
anticollision
select
Mifare 7 byte UID:
request (REQA)
anticollision level 1
select 1
anticollision level 2
select 2
The reader answers the UID of an active (non halt) transponder.
Input format:
GA
<CR>
Output (example):
625E562A
<CR>
3.4.2
GT – get tag
With the command GT you select a transponder. The command GT causes one reading cycle. There
are different cycles for different transpondertypes.
Mifare 4 byte UID:
request (WUPA)
anticollision
select