![AEG ACM 9 Manual Download Page 48](http://html.mh-extra.com/html/aeg/acm-9/acm-9_manual_3048210048.webp)
Manual ACM 9 - ARE i9 release
Version: 10
Page: 48 / 51
Manual ACM9_ARE i9 release V10.docx
3.6.10
LED (De)activate LED functionality (LED)
In order to deactivate (or activate) the LED functionality, LED instruction is used.
Input format:
LED<SP>Parameter<CR>
Hex:
53
54
42
20
30
OD
ASCII:
‘L’
‘E’
‘D’
<SP>
‘0’
<CR>
Output:
0<CR>
Hex:
30
0D
ASCII:
‘0’
<CR>
LED<SP> 0<CR> deactivates LED functionality.
LED<SP> 1<CR> activates LED functionality (default).
Above examples represent ARE i9 default values.