Cabinet minimum
height (Cabinet un-
der the worktop mini-
mum height)
469 – 472 (477 -
480) mm
Cabinet width
860 mm
Cabinet depth
560 mm
Height of the front of
the appliance
475 mm
Height of the back of
the appliance
466 mm
Width of the front of
the appliance
896 mm
Width of the back of
the appliance
848 mm
Depth of the appli-
ance
577 mm
Built in depth of the
appliance
554 mm
Depth with open
door
938 mm
Ventilation opening
minimum size. Open-
ing placed on the
bottom rear side
860 x 60 mm
Mains supply cable
length. Cable is
placed in the right
corner of the back
side
1500 mm
Mounting screws
4 x T20 mm
2.2
Electrical connection
WARNING!
Risk of fire and electric
shock.
• All electrical connections should be
made by a qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the
rating plate are compatible with the
electrical ratings of the mains power
supply.
• Always use a correctly installed
shockproof socket.
• Do not use multi-plug adapters and
extension cables.
• Make sure not to cause damage to
the mains plug and to the mains
cable. Should the mains cable need
to be replaced, this must be carried
out by our Authorised Service Centre.
• Do not let mains cables touch or
come near the appliance door or the
niche below the appliance, especially
when it operates or the door is hot.
• The shock protection of live and
insulated parts must be fastened in
such a way that it cannot be removed
without tools.
• Connect the mains plug to the mains
socket only at the end of the
installation. Make sure that there is
access to the mains plug after the
installation.
• If the mains socket is loose, do not
connect the mains plug.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• Use only correct isolation devices: line
protecting cut-outs, fuses (screw type
fuses removed from the holder), earth
leakage trips and contactors.
• The electrical installation must have
means for disconnection from the
supply mains having a contact
separation in all poles that provide full
disconnection under overvoltage
category III conditions and must be
incorporated in the fixed wiring in
accordance with the wiring rules.
• This appliance is supplied only with a
main cable.
• The tightening torque of the screws of
the terminal supply wires must be 1.5
- 2 Nm.
Cable types applicable for installation
or replacement:
H05 VV-F, H05 V2V2-F (T90)
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
ENGLISH