AED HeartPlus NT-180 User Manual & Warranty Registration Download Page 1

HeartPlus

 

 

 

User Manual & Warranty Registration 

 

 

©

2016  NANOOMTECH  CO.,  LTD  All  rights  are  reserved.  It  is  prohibited  to  reproduce  or 

duplicate, in any form, this manual or any part thereof without permission of  NANOOMTECH 

CO., LTD. 

   

This user manual may be changed without prior notice to users for functional improvements. If 

more  than  two  (2)  years  have  elapsed  since  the  revision  date  (listed  on  the  bottom  of  this 

page), please contact NANOOMTECH CO., LTD or your local distributor to determine whether 

additional product information updates are available. 

 

HeartPlus

 is a trademark of NANOOMTECH CO., LTD 

 

 

EM0101-2 (1810-REV06) 

Publisher: NANOOMTECH CO., LTD

This issue date for the HeartPlus

 User Guide, Rev. 6, is Oct 2018.

 

 

Device manufacturer 

 

NANOOMTECH CO.,LTD.   

Address: 57, Cheomdan venture so-ro, Bukgu, Gwangju, 61003, Rep. of Korea.   

 

Authorized EU Representative 

 

CMC Medical Devices & Drugs S.L. 

C/ Horacio Lengo Nº 18, CP 29006

Málaga, Spain

 

Tel: +34951214054 / Fax: +34952330100 / E-Mail: [email protected]

 

 

Summary of Contents for HeartPlus NT-180

Page 1: ...e bottom of this page please contact NANOOMTECH CO LTD or your local distributor to determine whether additional product information updates are available HeartPlus is a trademark of NANOOMTECH CO LTD...

Page 2: ...ii Intentionally Blank...

Page 3: ...4 PRODUCT INFORMATION 5 PRODUCT SPECIFICATION AND FUNCTION 6 SET CONFIGURATION 9 PRODUCT CHARACTERISTICS 11 DISPLAY DETAILS 12 NAME AND FUNCTION OF COMPONENTS 14 SECTION II PRODUCT USE 19 SIMPLE GUID...

Page 4: ...POST USE PRODUCT MANAGEMENT 41 STORAGE GUIDELINES 43 CAUTIONS FOR BATTERY PACK 44 GLOSSARY OF SYMBOLS 46 SECTION IV APPENDIX 49 DEFIBRILLATION WAVEFORM 50 CHARACTERISTIC OF ECG ANALYSIS 52 ELECTROMAGN...

Page 5: ...ance and operability If the HeartPlus NT 180 is sold donated lost stolen exported or destroyed please notify NANOOMTECH CO LTD or your local distributor The following visuals are used in this manual t...

Page 6: ...oximately 4cm 1 5inch for infants and approx 5cm 2inch for the child Achieve enough compression speed and depth allow the chest to recoil completely after each compression minimize interruptions in ch...

Page 7: ...3 Section I Product Introduction...

Page 8: ...culation of the blood due to the failure of the heart SCA can occur to anyone at anytime and anywhere SCA patients do not show any warning signs or symptoms Some individuals are at a higher risk of su...

Page 9: ...n I Product Introduction 5 Product Information Product Name AED Brand Name HeartPlus Model Name NT 180 NT 180Y NT 180B NT 180G Product Appearance Size 293mm W X 291mm L X 71mm H Weight 1 9kg Incl cart...

Page 10: ...ated external defibrillator which can analyze ventricular fibrillation Change Method to Pediatric Mode Power on device in Pediatric Mode small yellow button ECG Induction Method of ECG LEAD All in one...

Page 11: ...ype electrode pads can be used Size 150 W X 110 L X 33 H mm Warranty About five 5 years Sealed storage at room temperature Detachable Type Electrode Pads Disposable Area 86 44cm2 Hydro Gel Wire length...

Page 12: ...rged internally Over discharge protection circuit for proper discharging of defibrillation shock energy Safety control circuit to prevent the malfunction of the electric shock waveform control circuit...

Page 13: ...n body a cartridge and other components a towel a USB cable etc In case of cartridges there is All in one type of cartridges where an electrode pads and a battery are not separated and detachable type...

Page 14: ...t Introduction 10 Set Configuration options Cartridge All in one type electrode pads Consumables for a detachable type Cartridge detachable type electrode pads detachable type Other consumables Towel...

Page 15: ...lable Electrode pads can be used on both Adult and Pediatric patients However the attachment points are different After analyzing ECG signals for 5 seconds it stores them in the internal memory up to...

Page 16: ...c mode lamp Orange The pediatric LED light is lit when the pediatric mode is on Normal state The normal state Green When battery power is sufficient and device is functioning normally the pads attachm...

Page 17: ...oduct Introduction 13 ECG analysis Analyze ECG During analysis ECG analysis lamp flashes After completion of analysis ECG analysis lamp stays on Cardiopulmonary resuscitation Commence CPR CPR lamp sta...

Page 18: ...n shock button Red If the flashing defibrillation shock button is pressed a defibrillation shock is delivered Power button for Adult The Adult Mode power button prepares defibrillation shock mode for...

Page 19: ...ge beneath PUSH then lift the Cartridge Cover To open the cover push the hand picture on the right side to release and then lift the cover Microphone Microphone to record ambient sound during operatio...

Page 20: ...test via voice prompt Handle A handle to carry the equipment All in one type cartridge Cartridge consists of two parts the electrode pads and the battery When seal is opened a pair of electrode pads c...

Page 21: ...ctrode pads Electrode pads detachable type It has to be connected to a detachable type cartridge only Port for electrode pads connector detachable type The disposable electrode pads separated type is...

Page 22: ...Section II Product Use 18 Intentionally Blank...

Page 23: ...19 Section II Product Use...

Page 24: ...for Use 1 Press Adult or Pediatric power button 2 Put the electrode pads on the patient s bare skin by the proper placement guide 3 Press defibrillation shock button by voice prompt 4 Commence CPR 30...

Page 25: ...m or the case of an all in one cartridge is damaged you should exchange it for a new one 2 How to replace an expired all in one type cartridge After removing the sealing film of electrode pads push th...

Page 26: ...et rid of the protection film after installing an all in one type cartridge until situation where immediate usage is required You must take off the cartridge protective film before applying pads to th...

Page 27: ...color of connector into the detachable cartridge Plug the connector of the detachable electrode pads into the matching colored port on the detachable cartridge Don t open the sealing film until immed...

Page 28: ...e pads 2 Remove the patient s top clothing Note If necessary rip or cut off the clothing to bare the person s chest 3 If there is any water on the patient s body before attaching an electrode pads dry...

Page 29: ...ng Ensure to check if the electrode pads connector is connected to the separate cartridge 6 Place one pad on the patient s bare skin as shown in the picture Press the adhesive portion of the pad down...

Page 30: ...ad attachment is critical 7 Keep away from the patient according to the voice from the product Voice prompt Stay clear of patient User must stay clear of the patient and the HeartPlus device during an...

Page 31: ...mp flicks the electric shock energy will be delivered to the patient if you press the electric shock button Voice prompt Electric shock is done Lamp state Electrode pad attachment lamp and ECG analysi...

Page 32: ...ly pressure to the chest CPR Beep 30 chest compressions 2 rescue breaths Whoo Whoo Lamps to indicate the operation state The attachment of electrode pads and the electrocardiogram analysis lamp are on...

Page 33: ...Remove the patient s top clothing If necessary rip or cut off the clothing to bare the person s chest 3 If there is any water on a patient s body before attaching an electrode pad dry the body with a...

Page 34: ...envelope and then remove the protective film Ensure to check if the electrode pads connector is connected to the separate cartridge 6 Place the pad on the patient s bare skin exactly as shown in the...

Page 35: ...state Electrode pad lamp is already ON and ECG analysis lamp flickers After the ECG analysis is complete ECG analysis lamp is already ON 9 1 Situation requiring a defibrillation shock Voice prompt Per...

Page 36: ...ck button you might get a defibrillation shock also If you do not push the defibrillation shock button within 20 seconds defibrillation shock procedure will be cancelled If defibrillation shock proced...

Page 37: ...e Electrode pad attachment lamp and ECG analysis lamp are already ON CPR lamp flickers 10 2 An electrocardiogram of the patient is not analyzed while the cardiopulmonary resuscitation is being perform...

Page 38: ...arge Attachment of electrode pad the electrocardiogram analysis and the cardiopulmonary resuscitation lamp are all flashing Until the complete discharge of the battery Change the battery prompt will s...

Page 39: ...attachment ECG analysis and CPR lamps are lit together Find the recorded data using the data management program NT MPR Make sure the power is OFF Once HeartPlus is used on site the surrounding sound i...

Page 40: ...Section III Guidelines 36 Intentionally Blank...

Page 41: ...37 Section III Guidelines...

Page 42: ...d attach electrode pads 1 Electrode pads should be adhered to the patient s body in the same way as illustrated on the picture on the pads themselves and on the AED s main panel 2 If the patient s bod...

Page 43: ...on 6 The state of HeartPlus should be checked periodically 1 Self diagnostics test on circuitry which ensures device integrity is performed every day and in case that any problem occurs the state indi...

Page 44: ...recommend that you maintain at least a short distance between portable or mobile RF communication device transmitter and HeartPlus in order to eliminate any chance of negative effects to the device d...

Page 45: ...for our product is a disposable electrode pads Please refer to installation method of electrode pads specified in Chapter 2 Use of Product for the replacement of the electrode pads 3 Used cartridge p...

Page 46: ...s in green color it means equipment is operated normally If you have any problem contact our customer service center 5 After you keep the product in designated place you need to be prepared to use it...

Page 47: ...ntaminated by airborne dust and salt 3 Be careful of shock vibration impacts and etc Dropping or slamming the product may cause problems 4 Do not store where chemicals gas or fuel are being stored 5 I...

Page 48: ...metallic lithium reaction with moisture in the air The leaking electrolyte may generate heat and catch fire then the cartridge may emit smoke burst or ignite 3 Battery pack storage recommendations In...

Page 49: ...y contacting a waste disposal company is recommended and may be required by local laws 3 When discarding battery pack insulate the and terminals of batteries with insulation tape as shown below to avo...

Page 50: ...fore use Caution consult accompanying documents Do not indiscriminately throw cartridge batteries away Its exposure to moisture or external stimulation causing fire or explosion Type and Extent of Pro...

Page 51: ...ion Recommended temperature range Fragile handle with care Keep away from rain Keep away from sunlight Non rechargeable lithium battery Do not charge the battery This equipment is not allowed to be us...

Page 52: ...Section III Guidelines 48 Symbols Definition EU representative Date of manufacture Serial number Power ON OFF Catalog number Use by date...

Page 53: ...49 Section IV Appendix...

Page 54: ...ergy discharge time according to the patient impedance Energy output parameter Energy output time is automatically and adjusted by the impedance of the patient Error rate 10 Impedance Phase 1 duration...

Page 55: ...nergy output parameter Energy output time is automatically and adjusted by the impedance of the patient Error rate 10 Impedance Phase 1 duration ms Phase 2 duration ms Output energy J 25 2 8 2 7 48 3...

Page 56: ...rhythm Specificity 99 100 n 150 97 Asystole Specificity 95 100 n 100 92 Others Specificity 95 96 n 50 88 1 American heart Association AHA AED Task Force Subcommittee on AED Safety Efficacy Automatic E...

Page 57: ...munity Immunity test IEC60601 Test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6kV contact 8kV air 15kV contact 15kV air There are no special...

Page 58: ...rference if it is inadvertently brought into patient area c Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM...

Page 59: ...er where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80MHz and 800MHz the separation distance for the higher frequency range...

Page 60: ...diagnosing 4 Shock advisory Performing an electric shock Charge Beep 5 Defibrillation shock Press the flashing red button You did not press the electric shock button Cancel preparation for electric sh...

Page 61: ...s in good condition circuitry battery in operational state the power will be automatically off after self diagnosis 4 If there is an error not related to low batteries all lights will be flashing at t...

Page 62: ...en done manually and yields the same results as in the previous page When you approach a machine with all lights blinking but you are not certain whether it is a low battery issue or an actually equip...

Page 63: ...ar and tear from normal use Warranty Registration NANOOMTECH CO LTD guarantees this product for a period of five 5 years If servicing is needed please contact your local customer support center or dea...

Reviews: