11
Maintenance, de-installation and disposal
11.1
Maintenance of the controller
The controller is basically maintenance-free. Despite this, it is a good idea to regularly check that the
cooling ribs on the front and rear sides of the device are free of dust. Clean the inverter when neces-
sary as described below.
ATTENTION!
Danger of damage to components.
–
Do not allow cleaning agents or objects to enter the inside of the controller from the front.
–
Do not use especially the following cleaning agents:
–
Solvent-based cleaning agents
–
Disinfection agents
–
Coarse or sharp-edged cleaning agents
11.1.1
Removing dust
u
Dust should be removed using compressed air (max. 2 bar).
11.1.2
Removing heavy soiling
DANGER!
Risk of death by electrocution.!
–
Switch off the solar module and battery before cleaning, as described in
–
Use cleaning agents only with a slightly damp cloth.
u
Remove heavy soiling with a slightly damp cloth (use clear water). If necessary, use a 2 %
hard soap solution instead of water. After cleaning, remove any soap residue using a slightly
damp cloth.
11.2
System maintenance
We recommend checking all system components at least once a year, according to the manufactur-
er's specifications. The following maintenance work is generally recommended:
n
Check the cable strain relief.
n
Check that all cable connections are secure.
DANGER!
Risk of death by electrocution.. Only technical professionals are permitted to remove the terminal
cover.
n
Tighten screws if necessary
n
Check all contacts for signs of corrosion.
n
Check the acid levels in the battery according to the manufacturer's specifications
GB