USER'S GUIDE
INSTALLATION
PK232UG Rev. B 9/86
2-8
26
2.5.1
Display Complete Command List
At the
cmd:
prompt, type the command word
DISPLAY Z
. The PK-232 displays the en-
tire list as shown in APPENDIX A.
The DISPLAY Z command shows the complete command list and the ROM default values
installed at time of manufacture, assigned to those parameters that take values. The de-
fault shown, below are in effect when the PK-232 is turned on for the first time and each
time that you type the RESET command.
2.5.2
Display Partial Command Lists
The command list can be displayed in sections according to the class of parameter or
function you wish to see. The
DISPLAY
function is divided into the following six classes:
A
Asynchronous port parameters
C
Special characters
I
Identification parameters
L
Link parameters
M
Monitor parameters
R
RTTY parameters (includes Morse, Baudot, ASCII and AMTOR)
T
Timing parameters
Z
All parameters displayed
The following paragraphs list the commands by class with a brief explanation of each
command's function.
2.5.3
Display Asynchronous Port Parameters
cmd:
disp a
8BITCONV
OFF
Strip bit 7 in CONVERSE
ACRDISP
80
Screen width
ALFDISP
ON
Send <LF> after <CR> to terminal
AWLEN
7
Data bits per word, to terminal
ECHO
ON
Echo typed keyboard characters
ESCAPE
OFF
Send ESC character $1B as $24
FLOW
ON
Stop echo to screen while typing
LCOK
ON
Accept lower case to terminal
NUCR
OFF
Nulls to terminal after <CR>
NULF
OFF
Nulls to terminal after <LF>
NULLS
0
Number of nulls for NUCR & NULF
PARITY
3
Terminal program parity (0-3)
TBAUD
1200
Terminal baud rate
TRFLOW
OFF
Terminal flow control - Transparent
TXFLOW
OFF
PK-232 flow control - Transparent
XFLOW
ON
Software flow control