AIR50-2230A Operation Manual
Project Maintenance Process
61
10.
Install the cover plate of manipulator and coat the joint with sealant.
11.
Perform the calibration for J5 axis of manipulator.
Figure 13-12Removal of Cover Plate
Figure 13-13 Removal the motor flange of J5
Figure 13-14 Remove Synchronous Belt
Warning
◼
After the replacement of synchronous belt, the J5 axIs of manipulator
shall be calibrated. For details, see
Chapter 10
of this manual
。
M4 screw
Cover plate
M5 screw
M5 screw
motor
Synchronous belt