R3267 Series Spectrum Analyzer Operation Manual (Vol.1)
3.3.25 UTIL Key (Utility)
3-81
Start Offset
Sets the lower limit of the phase noise integration range.
Stop Offset
Sets the upper limit of the phase noise integration range.
Signal Track ON/OFF
Toggles the signal track mode on or off.
ON:
The signal track mode is turned on, and measurements
are taken by keeping track of the carrier frequency,
which results in changes to the center frequency.
OFF:
Turns the signal track mode off.
Average Times ON/OFF
Toggles the trace averaging function on or off.
ON:
Sets the number of averaging times, traces and then av-
erages the phase noise waveform for each offset fre-
quency.
OFF:
Turns the trace average function off.
Phase Jitter OFF The phase noise measurement function is turned off, and the
Phase Noise menu is displayed.
IM Meas
Displays the IM Meas menu in two-screen mode. Traces are dis-
played on the upper screen, and odd-harmonic measurement data
is displayed on the lower screen.
Order
Sets the degrees used. The degrees available are 3, 5, 7 and 9.
Limit Setup
Displays the Limit Setup dialog box.
3rd Order
Sets the limit value for a third-order harmonic signal.
5th Order
Sets the limit value for a fifth-order harmonic signal.
7th Order
Sets the limit value for a seventh-order harmonic signal.
9th Order
Sets the limit value for a ninth-order harmonic signal.