![Advantech Zlinx BB-ZP9D115RMLR-A User Manual Download Page 23](http://html1.mh-extra.com/html/advantech/zlinx-bb-zp9d115rmlr-a/zlinx-bb-zp9d115rmlr-a_user-manual_2858269023.webp)
BB-ZP9D115RMLR-A Radio Modem
19
COMMAND REFERENCE TABLE
ZLINX COMMANDS
Note: Zlinx Radio Modems expect numerical values in hexadecimal. Hexadecimal values
are designated by a “0x” prefix. Decimal equivalents are designated by a “d” suffix.
AT _
Command
Binary _
Command AT Command Name
Parameter
Range
Command _
Category
# Bytes
Returned
Factory
Default
%V
0x3B (59d) Board Voltage
0x2CCCA -
0x5BFFA
[read-only]
Diagnostics
4
--
AM
0x40 (64d) Auto-set MY
--
Networking &
Security
--
--
AP v2.x20* --
API Enable
0 - 2
Serial Interfacing 1
0
AT
0x05 (5d) Guard Time After
2 - (ATST-3)
[x 100 msec]
Command Mode
Options
2
0x0A (10d)
BD
0x15 (21d) Interface Data Rate
0 - 8 (standard
rates)
0x39 -
0x1C9C38
(non-standard
rates)
Serial Interfacing 4
3
BR
0x39 (57d) RF Data Rate
0 - 1
RF Interfacing
1
1
BT
0x04 (4d) Guard Time Before 0 - 0xFFFF
[x 100 msec]
Command Mode
Options
2
0x0A (10d)
CC
0x13 (19d) Command Sequence
Character
0x20 - 0x7F Command Mode
Options
1
0x2B ["+"]
(43d)
CD
0x28 (40d) GPO2 Configuration 0 - 4
Serial Interfacing 1
2
CF
--
Number Base
0 - 2
Command Mode
Options
1
1
CN
0x09 (9d) Exit Command Mode --
Command Mode
Options
--
--
CS
0x1F (31d) GPO1 Configuration 0 - 4
Serial Interfacing 1
0
CT
0x06 (6d) Command Mode
Timeout
2 - 0xFFFF
[x 100 ms]
Command Mode
Options
2
0xC8 (200d)
DB
0x36 (54d) Received Signal
Strength
0x6E - 0x28
[read-only]
Diagnostics
2
--
DT
0x00 (0d) Destination Address 0 - 0xFFFF
Networking &
Security
2
0
E0
0x0A (10d) Echo Off
--
Command Mode
Options
--
--
E1
0x0B (11d) Echo On
--
Command Mode
Options
--
--