WISE-6610 Series User Manual
87
3.
To get the sensor node data, the application server needs to be enabled first.
After the application server is enabled, the Advantech application server will
parse the data subscribed from the MQTT broker (WISE-6610 with topic uplink/
#) as shown in the figure below.
Figure 4.29 User Modules > LoRaWAN Gateway > MQTT and LoRaWAN
4.
Click
LoRaWAN Server
>
Devices
>
Activated (Nodes)
to enter the Nodes
List page.
Figure 4.30 LoRaWAN Server > Activated (Nodes)
5.
Edit the LoRa Node and enter
Advantech
in the
App Arguments
field. The
Advantech application server will deal with the raw data based on the info and
list the real data on the
Advantech Application
page.
Figure 4.31 LoRaWAN Server > Activated (Nodes) > Edit > General