Summary of Contents for SPC-530

Page 1: ...SPC 530 Rackmount Server PC User s Manual...

Page 2: ...ate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgments SPC 530MB SPC 530...

Page 3: ...nsions 4 Chapter 2 System Setup 5 2 1 Removing the cover 5 2 2 Removing the handles 6 2 3 The cooling fans 6 2 5 Temperature setting 7 2 4 Installing the disk drives 7 2 6 Installing the power supply...

Page 4: ...g d i r t r a C k s i D s t e s 5 x P B 0 3 5 C P S e n a l p k c a b e v i s s a p t o l s 0 2 S E Y B M 0 3 5 C P S r o f e c a p s e h t e v r e s e R d r a o b r e h t o m X T A S E Y C 2 U P B 0...

Page 5: ...o M e n a l p k c a B t n e m g e S r e p s t o l S s t n e m g e S 4 P 0 2 1 6 A C P G M C I P 1 I C P 4 A S I 5 1 e l g n i S 7 P 9 1 1 6 A C P G M C I P 1 I C P 7 A S I 1 1 e l g n i S 7 1 P 9 1 1...

Page 6: ...alarm also sounds The LED remains red until the temperature drops below 63o C Temperature select The temperature threshold can be adjusted to one of four readings by setting the switch on the alarm b...

Page 7: ...4 SPC 530 User s Manual 1 4 Dimensions Unit mm SPC 530BP Can be fitted with a 20 slot backplane SPC 530MB Can be fitted with a 12 x 13 motherboard...

Page 8: ...also gather together all of the cards you plan to install as well as the disk drives you plan to use WARNING Disconnect all power from the chassis before you install the CPU cards Unplug the power cor...

Page 9: ...ed as follows Please see Figure 2 2 below 2 3 The cooling fans There are three cooling fans inside the chassis To replace or service the fans open the top cover as in Figure 2 1 Loosen the thumbscrews...

Page 10: ...rive bay and insert the drives into their proper locations in the drive bay See Figure 2 5 2 5 Inserting the drives into the drive bay 2 5 Temperature setting If the chassis interior temperature excee...

Page 11: ...s Manual 2 6 Installing the power supply unit There is one 400 W ATX redundant power supply installed at the front of the chassis The power module can be hot swapped for maintainence 2 7 ATX redundan...

Page 12: ...ors provide an impedance mismatch at the end of the bus to prevent signal reflections This mismatch has to be balanced by the capability of the CPU and optional cards to electrically drive the load im...

Page 13: ...10 SPC 530 User s Manual PCA 6119P7 Rev A1 15 ISA 4 PCI 1 PICMG slot passive backplane Dimensions 420 x 260 mm...

Page 14: ...SPC 530 User s Manual 11 PCA 6119P17 Rev A1 1 ISA 17 PCI 1 PICMG slot passive backplane Dimensions 420 x 260 mm...

Page 15: ...12 SPC 530 User s Manual SPC 530MB Appendix B Exploded Diagrams...

Page 16: ...SPC 530 User s Manual 13 SPC 530BP...

Page 17: ...d 10 All cautions and warnings on the equipment must be noted 11 If the equipment is not used for a long time disconnect it from the mains This prevents the equipment from being damaged by transient o...

Reviews: