background image

 

User’s Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-100-RT 

1U Server 

Summary of Contents for RS-100-RT

Page 1: ...User s Manual RS 100 RT 1U Server...

Page 2: ...written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor...

Page 3: ...rworks Corporation All other product names or trademarks are properties of their respective owners CE Notification RS 100 RT S3 S3 developed by Advantech Co Ltd has passed the CE test for environment...

Page 4: ...accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous te...

Page 5: ...ion readily available 3 If your product is diagnosed as defective obtain an RMA return merchandise authorization number from your dealer This allows us to process your return more quickly 4 Carefully...

Page 6: ...s l 8 Screw Sinks for Ears and Handlers l 1 CD Title Driver Bank l 4 Driver Bank Floppy Diskettes including RAID l RS 100 RT User s Manual l Warrant Card Technical Support and Sales Assistance If you...

Page 7: ...and Installation 20 2 1 System Placement 20 2 2 Motherboard Placement 21 2 3 SCSI Backplane Placement 24 2 4 Installing CPU 25 2 5 Installing CPU Cooler 28 2 6 Installing System Memory 30 2 7 Install...

Page 8: ...59 3 2 8 Exit without Saving 60 Chapter 4 Drivers Installation 61 4 1 Drivers for Windows NT 4 0 62 4 2 Drivers for Windows 2000 66 4 3 Drivers for Red Hat Linux 7 0 7 1 68 Appendix A Memory Approval...

Page 9: ...RS 100 RT User s Manual 8...

Page 10: ...thin servers is well placed to compete at the forefront in this fast paced product sector Thin servers are rapidly becoming the platform of choice for Internet VOD Video on Demand industrial and tele...

Page 11: ...capacity high speed hot swappable SCSI storage devices high speed network interfaces and specially designed fault detection and management features These all add up to a hardware solution that provide...

Page 12: ...i RageXL with 4MB SGRAM SCSI Adaptec 7899W Ultra 160 dual channel controller data transfer rate up to 160MB s Each channel can support 3 internal SCSI HDD RAID HW zero channel RAID module option LAN T...

Page 13: ...ap SCA 2 SCSI HDD drive bays 1 slim type FDD drive and 1 slim type CD ROM drive Power Supply 300W power supply Input 90 264VAC Full Range 47 63Hz System Monitoring Integrated server management feature...

Page 14: ...RS 100 RT User s Manual 13 Dimension 426mm 19 W x 44mm 3 46 H x 600mm 23 6 D Certifications FCC Class A CE UL CUL BSMI OS Linux Free BSD 4 x Win 2K NT 4 0 Solaris 8 x...

Page 15: ...able for attaching USB devices User can plug USB device directly to the USB connector LAN Connectors 8 pin The serverboard provides three LAN connectors with two status LEDs One LED indicates whether...

Page 16: ...Parallel Port EPP and Extended capabilities Parallel Port ECP PS 2 Mouse Connector 6 pin Female The connector is for a standard PS 2 mouse only Serial Port Connector The serverboard has one 9 pin mal...

Page 17: ...Switch LEDs CDROM FDD HDD1 HDD2 HDD3 l System Status Panel Indicator Description Voltage Red Voltage Redundant Power Failure Temperature Red Overheating Fan Red Fan Failure LAN 1 Green Active LAN 2 G...

Page 18: ...re The fans are set for their normal RPM range and alarm threshold If an alert is triggered that means a failure status occurs The system will signal a red light on the front panel and the buzzer soun...

Page 19: ...riggered that means a failure status occurs The system will signal a red light on the front panel and the buzzer will sound to alert Even if the Alarm Reset button and the system mute are pressed the...

Page 20: ...RS 100 RT User s Manual 19 The system provides an optional SNMP MIB base software that allows user to monitor the current health status of this machine via network management software at remote site...

Page 21: ...RS 100 RT User s Manual 20 Chapter 2 System Placement and Installation 2 1 System Placement Power Supply Motherboard FAN...

Page 22: ...Socket LAN Module SCSI Port Ch B Power module P CPU0 socket CPU1 socket FDD port IDE port Power Connector Note If machine installs one CPU only please insert it in CPU0 socket Terminator board should...

Page 23: ...ault For LED board system reset bottom S2 2 3 Closed System Reset For LED board system reset bottom S2 l J6 LAN1 LAN2 LED indicator Function Jumper On board 82559 LAN1 LED PIN 1 2 Closed On board 8255...

Page 24: ...8 5 ON OFF ON ON 1 13Ghz 9 OFF OFF ON ON 1 2Ghz 9 5 OFF ON ON ON 1 26Ghz 10 OFF ON OFF OFF 1 33Ghz 10 5 ON ON OFF ON 1 4Ghz 11 ON OFF OFF OFF 1 46Ghz 11 5 OFF ON OFF ON 1 53Ghz 12 ON OFF OFF ON 1 6Gh...

Page 25: ...e Placement 2 3 1 SCA 2 SCSI Backplane l RS 100 RT Connector Description CN2 SCSI HDD Active Indicator CN3 68 pin SCSI Connector to Host CN5 Power Connector CN6 SCA 2 SCSI HDD Connector ID 3 CN7 SCA 2...

Page 26: ...Socket 370 CPU sockets that can accommodate Intel Tualatin CPUs as noted in the server specification table The server is designed to use dual CPU configuration The installed CPUs should be l The same...

Page 27: ...emove its cover and follow the directions below that come with the CPUs Always observe static electricity precautions when installing CPUs The general procedure is Pull the lever outward Raise the ret...

Page 28: ...tch the arm to the side of the socket Repeat this operation for the second CPU If you will only install one CPU it is necessary to install an optional CPU terminator in another slave CPU socket The pr...

Page 29: ...ill need to install the proper cooling device for the CPU The server comes with two high efficiency heatsink CPU coolers that sit on the top of an installed CPU and clip onto the CPU socket The genera...

Page 30: ...on the side of CPU socket Place the clip to hold the protrusion on another side of CPU socket Press the spring clip over the protrusion so that it snaps in place Plug the power connector of CPU cooler...

Page 31: ...pe of clamp style fan or else damage may occur to the CPU socket and or the CPU itself Note In order to upgrade to support higher speed CPU manufacture maybe changes to use new CPU cooler fan 2 6 Inst...

Page 32: ...ining latches back out of the way Orient the module so that the e dge connector sections correctly match the socket sections Holding the module to the socket place it in the socket so that the edge co...

Page 33: ...s on OS support It means if OS only supports system memory up to 2GB then the system with this OS installed also supports system memory up to 2GB 2 7 Installing Add on Card There are one expansion slo...

Page 34: ...User s Manual 33 Remove the pre installed bracket And assembly it with add on card bracket first Vertically put down the riser card with add on card and bracket Fasten the bracket of the bracket witha...

Page 35: ...can buy the LAN module from your dealer near you Please plug the third LAN module into the 80 pin connector CN11 located on Main Board and fasten it with M3 screw Please refer to 2 2 Main Board Place...

Page 36: ...They are supported by all major network operating systems Three onboard RJ 45 jacks provide convenient 10 100Base T RJ 45 operations 2 9 Installing Zero Channel Hardware RAID Module The machine provid...

Page 37: ...Adding Disk Drives The RS 100 RT has preinstalled three six hard disk drive bays one slim type CD ROM or DVD ROM master mode only and one slim type floppy disk drive The RS 100 RT provides one SCA 2...

Page 38: ...rder to install the hard disk drives in the chassis please follow the procedures below Unfasten the dummy HDD tray from the hard disk rack Put the hard disk drive in the hard rack and fasten it with s...

Page 39: ...RS 100 RT User s Manual 38 Close the latches Slide the cages of the HDD drive into HDD bays and make HDD drive connectors connect the SCSI sockets on SCSI backplane closely...

Page 40: ...RS 100 RT User s Manual 39 2 11 Installing Rail Slider...

Page 41: ...RS 100 RT User s Manual 40...

Page 42: ...BIOS optimized default settings as they come from the factory If you want to check or alter BIOS settings run the CMOS Setup Utility by pressing the Del key command during the POST If you think the s...

Page 43: ...unction keys of sub menu are described as below Key Function Description Esc Jump to Exit menu or return to the main menu from sub menu or Move the cursor to the up or down between fields or Select th...

Page 44: ...RS 100 RT User s Manual 43 3 2 Main Menu When the Setup program is accessed the following screen appears Move arrow keys to the appropria te place you will setup and press Enter for selection...

Page 45: ...tures allows users to configure system components such as date time hard disk drive and floppy drive types showed in the screen below Date mm dd yy Set the system date The format is month day and year...

Page 46: ...RT User s Manual 45 IDE Primary Master Move the highlight to the IDE Primary Master and enter to get the following screen IDE HDD Auto Detection To auto detect the capacity cylinder head and sector o...

Page 47: ...RS 100 RT User s Manual 46 IDE Primary Master Auto Manual None Access Mode Auto Large LBA CHS...

Page 48: ...DE Secondary Master Choose the option then get the following three items IDE HDD Auto Detection To auto detect the capacity cylinder head and sector of HDD IDE Secondary Master Auto Manual None Access...

Page 49: ...RT User s Manual 48 Drive A Set the type of floppy drive installed by Page Up Key and Page Down Halt On Set system halt on when specified item occurs The selection items are showed in the following s...

Page 50: ...Disabled Allows the system to skip certain tests while booting This will decrease the time needed to boot the system First Boot Device Floppy SCSI CD ROM HDD LAN Disabled Select your boot device prio...

Page 51: ...is 40 or 80 tracks A 360 KB type drive is 40 tracks while 720 KB 1 2 MB and 1 44 MB type drives are all 80 tracks Disable BIOS will not search for the floppy drive type by track number Gate A20 Optio...

Page 52: ...urity Option System Setup The setting determines whether the system will boot up if the password is denied Access to Setup is however always limited System The system will not boot and access to Setup...

Page 53: ...Board PCI IDE controller the user must choose which channels to disable This will depend on the channel used in the PCI Off Board add on card IDE Primary Master Slave PIO Auto Mode0 Mode 1 4 Each chan...

Page 54: ...low the system to use USB keyboard without device driver IDE HDD Block Mode Enabled Disabled Enabled allows the Block mode access for the IDE HDD Onboard FDC Controller Enabled Disabled The system has...

Page 55: ...set with 2 serial ports The On board serial ports can be selected as Auto Disable 3F8 IRQ4 COM 1 uses IRQ4 2F8 IRQ3 COM 2 uses IRQ3 Reserved for Internal Alarm Board 3E8 IRQ4 COM 3 uses IRQ4 2E8 IRQ3...

Page 56: ...d Enabled Default i s Disabled Select Enabled to reset Extended System Configuration Data ESCD when you exit Setup if you have installed a new add on and the system reconfiguration has caused such a s...

Page 57: ...properly The setting Enabled should correct this problem Otherwise leave this on the setup default setting of Disabled Recommend set Disabled State After Power Failure The field let you determine whic...

Page 58: ...s The option allows you to load the optimized default values for each of the parameters on the Setup menus When this option is pressed a confirmation is requested Select Y to load the optimized defaul...

Page 59: ...ss Enter Type password and press Enter You can type up eight alphanumeric characters If the CMOS is good or if this option has been used to change the default password the user is asked for the passwo...

Page 60: ...ish your selection choose the option to save the values you selected to CMOS RAM The CMOS RAM is sustained by an on board backup battery and stays on even system is turned off Once the option is selec...

Page 61: ...ng The option should only be used if you do not want to save the changes you have made to the Setup program If you have made changes to the fields the system will ask for confirmation before existing...

Page 62: ...the machine please download drivers from the website http access1 sun com patch public cgi bin show_list cgi un b Solaris_x86_Intel_Drivers The server provides an optional zero channel hardware RAID...

Page 63: ...e CD disc for Driver Bank there are some options as below when running Setup or CD auto run l VGA driver installation Please select the item RS100 200 RT Drivers Please click Install VGA driver then C...

Page 64: ...mputer s configuration 2 When the Windows NT Setup window is generated select Other and press Enter 3 Insert the Adaptec 7899 SCSI Driver for Win NT 4 0 diskette into Drive A and press ENTER 4 Select...

Page 65: ...sn t have zero channel RAID please skip the following procedure 1 Please finishWin NT 4 0 SP6 installation first 2 Double click My Computer icon 3 Select Control Panel icon 4 Choose SCSI Adapter icon...

Page 66: ...RS 100 RT User s Manual 65 For more information about how to setup RAID please retrieve the file RAID_USER_GUIDE PDF located in the subdirectory RS 100 RT RAID of Driver Bank CD...

Page 67: ...indows 2000 l VGA driver installation Please select the item RS100 200 RT Drivers Please click Install VGA driver then Choose Win2000 Double click setup exe Please follow the instructions showed on th...

Page 68: ...ated press Enter 3 In the Setup Method dialog box press Enter to confirm Express Setup 4 Press S to add a SCSI adapter 5 Specify a insert the Adaptec I2O RAID Host Adapters for Windows 2000 diskette i...

Page 69: ...r Windows2000 RS200 RT broadcom Drivers for Windows 2000 4 3 Drivers for Red Hat Linux 7 0 7 1 l Adaptec I2O RAID Host Adapter Driver for Linux Red Hat 7 0 7 1 1 Boot from CD ROM Insert floppy diskett...

Page 70: ...Insert your driver disk please press OK 5 Then follow the instructions showed on the screens For more information about how to setup RAID please retrieve the file RAID_USER_GUIDE PDF located in the su...

Page 71: ...RS 100 RT User s Manual 70...

Page 72: ...G 1G Bytes SMART SM572164574E63R SAMSUNG 128M Bytes SMART SM572324574E03R SAMSUNG 256M Bytes SMART SM572644578E63R SAMSUNG 512M Bytes SMART SM572284578E83R SAMSUNG 1G Bytes Apacer 128M Bytes Apacer 25...

Page 73: ...RS 100 RT User s Manual 72 Appendix B Giga bits LAN Card approval list Card Vendor Card Part No Chip Part No Intel Intel PRO 1000T Server Adapter TL82543GC Broadcom BCM95701A10 BCM5701H...

Page 74: ...D 3000S PCI64 bits 66MHz Dual channel Ultra 160 Mylex AccleRAID 352 PCI64 bits 66MHz Dual channel Ultra 160 Adaptec SCSI RAID 2100S PCI32 bits 33MHz Single channel Ultra 160 Mylex AccleRAID 170 PCI32...

Page 75: ...05S 2 96960210A0 LAN module for 3rd LAN port 3 9689000425 Rail Slider for RS 100 RT 4 SNMP 100L SNMP 100L 5 SNMP 100N SNMP 100N Appendix E ZCR RAID Utility Please refer CD ROM with P N 206202000x Open...

Page 76: ...the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting equipment to the power o...

Page 77: ...nt has been dropped and damaged f The equipment has obvious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 4 OR ABOVE 60 140...

Page 78: ...oder Fallen K nnte Verletzungen hervorrufen 7 Die Bel ftungs ffnungen dienen zur Luftzirkulation die das Ger t vor berhitzung sch tzt Sorgen Sie daf r da diese ffnungen nicht abgedeckt werden 8 Beach...

Page 79: ...setzt d Wenn das Ger t nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Ger t ist gefallen und oder das Geh use ist besch d...

Reviews: