3.14 Field Wiring Considerations
When you use the PCI-1220U to acquire data from outside, noises in the
environment might significantly affect the accuracy of your measure-
ments if due cautions are not taken. The following measures will be
helpful to reduce possible interference running signal wires between sig-
nal sources and the PCI-1220U.
• The signal cables must be kept away from strong electromagnetic
sources such as power lines, large electric motors, circuit breakers or
welding machines, since they may cause strong electromagnetic inter-
ference. Keep the analog signal cables away from any video monitor,
since it can significantly affect a data acquisition system.
• If the cable travels through an area with significant electromagnetic
interference, you should adopt individually shielded, twisted-pair wires
as the analog input cable. This type of cable has its signal wires twisted
together and shielded with a metal mesh. The metal mesh should only
be connected to one point at the signal source ground.
• Avoid running the signal cables through any conduit that might have
power lines in it.
• If you have to place your signal cable parallel to a power line that has a
high voltage or high current running through it, try to keep a safe dis-
tance between them. Or you should place the signal cable at a right
angle to the power line to minimize the undesirable effect.
• The signals transmitted on the cable will be directly affected by the
quality of the cable. In order to ensure better signal quality, we recom-
mend that you use the PCL-10152 shielded cable.
It is optional to connect encoder A/B phase
feedback signal. If connect to encoder signal,
user can read the real position from PCI-1220U.
If the environment has high noise or the
connection is long, we recommend you to use
twist pair cable for servo drives.
Summary of Contents for PCI-1220U
Page 1: ...PCI 1220U 2 axis Universal PCI Stepping Pulse type Servo Motor Control Card User Manual...
Page 16: ...PCI 1220U User Manual 10...
Page 19: ...13 Chapter 3 Figure 3 1 I O Connector Pin Assignments...
Page 42: ...PCI 1220U User Manual 36...
Page 43: ...2 APPENDIX A Specifications...
Page 48: ...PCI 1220U User Manual 42...
Page 49: ...2 APPENDIX B Block Diagram...
Page 50: ...PCI 1220U User Manual 44 Appendix B Block Diagram...
Page 51: ...2 APPENDIX C Wiring with Third Party Motor Drivers...
Page 53: ...47 Chapter C Figure C 2 Oriental LIMO EZMC Motor Driver...
Page 54: ...PCI 1220U User Manual 48 Figure C 3 Panasonic MINAS A Series Motor Driver...
Page 55: ...49 Chapter C Figure C 4 Yaskawa SGDM Series Motor Driver...
Page 56: ...PCI 1220U User Manual 50...