15
IDK-1107WP User Manual
Chapter 3
S
ignal Characteristics
3.3.2
Input Timing Diagram
3.4
Power ON/OFF Sequence
VDD power and lamp on/off sequence is as follows. Interface signals are also shown
in the chart. Signals from any system shall be Hi-Z state or low level when VDD is off.
Parameter Value
Unit
Min. Typ. Max.
T1 0.5
-
10
[ms]
T2 0
-
50
[ms]
T3 0
-
50
[ms]
T4 500
-
-
[ms]
T5 20
-
-
[ms]
T6 10
-
-
[ms]