85
EKI-9228G Series User Manual
The following table describes the items in the previous figure.
To add a new policy list:
Click System > Advanced Configuration > Event Manager > Policy List > Add.
Figure 4.79 System > Advanced Configuration > Event Manager > Policy List >
Add
The following table describes the items in the previous figure.
Policy Selection
Item
Description
List Name
The name of the policy list. This field can be configured only when
adding a new policy list.
Event Options
The method(s) used to decide which events will be applied to event
alarm action (Alarm LED, Alarm Relay, Alarm Relay 2, Logging, or
Trap).
List Type
The type of list, which is one of the following:
Default: The list is preconfigured on the system. This type of list
cannot be deleted, and only the Event Options are configurable.
Configured: The list has been added by a user.
Refresh
Click Refresh to update the screen.
Add
Click Add to add a new policy list.
Edit
Click Edit to edit the selected entries.
Item
Description
List Name
The name of the policy list. This field can be configured only when
adding a new policy list.
Event Options
The method(s) used to authenticate a user who attempts to access
the management interface or network. The possible methods are as
follows:
Link Change Members: The port(s) included in the link-change
event. If the event that meets the policy criteria that is in the Link
Change Members list, it is applied to Alarm LED, Alarm Relay,
Alarm Relay 2, Logging, or Trap. To add source ports to the pol-
icy, select one or more ports from the Available Port List field
(CTRL + click to select multiple ports). Then, use the appropriate
arrow icon to move the selected ports to the Link Change Mem-
bers field.
Submit
Click Submit to save the values.
Cancel
Click Cancel to close the window.
Summary of Contents for EKI-9228G-8CMI
Page 1: ...User Manual EKI 9228G Series 16xRJ45 4xSFP 8xCombo Port Full Gigabit L2 Managed Switch...
Page 18: ...EKI 9228G Series User Manual xviii A 1 Troubleshooting 305...
Page 19: ...Chapter 1 1Product Overview...
Page 23: ...Chapter 2 2Switch Installation...
Page 36: ...Chapter 3 3Configuration Utility...
Page 41: ...Chapter 4 4Managing Switch...
Page 322: ...Appendix A ATroubleshooting...