Page 1: ...EKI 7626C Industrial 16 2G Combo Ports Managed Redundant Fast Ethernet Switch User Manual ...

Page 2: ...rm or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DO...

Page 3: ...placement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer an...

Page 4: ...iate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site...

Page 5: ...nything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service ...

Page 6: ...mage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components ...

Page 7: ... 2 4 Top View of EKI 7626C 14 2 3 Mounting 15 2 3 1 Wall mounting 15 Figure 2 5 Combine the Metal Mounting Kit 15 2 3 2 DIN rail Mounting 16 Figure 2 6 Installation to DIN rail Step 1 16 Figure 2 7 Installation to DIN rail Step 2 17 2 4 Network Connection 18 2 5 Connection to a Fiber Optic Network 18 Figure 2 8 Transceiver to the SFP module 18 Figure 2 9 Transceiver Inserted 19 Figure 2 10 LC conn...

Page 8: ...EKI 7626C User Manual viii ...

Page 9: ...1 Chapter1 Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER ...

Page 10: ...nsmission mode and distance of the switch by simply pulling out the SFP module and plugging in a different module The SFP modules are hot swappable and plug and play Also the fact that the switch has two of these slots means that the network manager can for example have one 10km module in one slot and one 110km in the other 1 1 2 High Speed Transmissions The EKI 7626C includes a switch controller ...

Page 11: ... the EKI 7626C in some of the harshest industrial environments that exist 1 1 7 Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators PWR1 PWR2 and P Fail help you diagnose immediately ...

Page 12: ...plane Switching Fabric 7 2Gbps 1Mbits Packet Buffer 8K MAC Address Table Supports Wide Operating Temperature 40o C 75o C Power Supply Wide Range Redundant Power Design Power Polarity Reverse Protect Overload Current Protection Case Installation IP 30 Protection DIN Rail and Wall Mount Design Provides EFT protection 3 000 VDC for power line Supports 4 000 VDC Ethernet ESD protection Future release ...

Page 13: ... 1000Mbps Interface Connectors 16 x RJ 45 Ethernet 2 x RJ 45 SFP mini GBIC combo ports 6 pin removable screw terminal power Relay LED Indicators System PWR1 PWR2 P Fail 10 100TX Link Activity Duplex Collision Gigabit Copper Link Activity Speed 1000Mbps SFP Link Activity Power Power Consumption Max 9 W Power Input 2 x Unregulated 12 48 VDC Fault Output 1 Relay Output Mechanism Dimensions WxHxD 79 x...

Page 14: ... condensing Storage Temperature 40 85 40 185 Storage Humidity 0 95 non condensing MTBF 284 409 hours Certifications Safety UL 60950 1 CAN CSA C22 2 No 60950 EMC EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 11 12 EN61000 6 2 Freefall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 ...

Page 15: ...OM with software and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x DC Jack cable φ2 0 150mm 1 x EKI 7626C Startup Manual 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Page 16: ...EKI 7626C User Manual 8 ...

Page 17: ...9 Chapter3 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Connection to a Fiber Optic Network z Power Connection CHAPTER ...

Page 18: ... Fail Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both active or no power input Link Active for G17 G18 SFP Green On SFP port is linking Flashing Data is transmitting or receiving Off Not connected to network G17 G18 RJ 45 Green Upper LED On Connected to network Flashing Networking is active Off Not connected to network Green Lower LED On The port is operating at speed of 100...

Page 19: ...11 Chapter3 2 2 Dimensions units mm Figure 2 1 Front View of EKI 7626C ...

Page 20: ...EKI 7626C User Manual 12 Figure 2 2 Side View of EKI 7626C ...

Page 21: ...13 Chapter3 Figure 2 3 Rear View of EKI 7626C ...

Page 22: ...EKI 7626C User Manual 14 Figure 2 4 Top View of EKI 7626C ...

Page 23: ...l mounted by using the included mounting kit Then hang on the EKI 7626C to the nails on the wall First use the screws included in the package to combine the EKI 7626C and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below Figure 2 5 Combine the Metal Mounting Kit ...

Page 24: ...teps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 7626C to the DIN rail with angle of inclination See Figure 2 6 Figure 2 6 Installation to DIN rail Step 1 ...

Page 25: ...17 Chapter3 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 ...

Page 26: ...for connecting to the network segment with single or multi mode fiber You can choose appropriate mini GBIC module to plug into the slot Make sure the module is aligned correctly and then slide the module into the SFP slot until a click is heard You can use proper multi mode or single mode fiber according to the used SFP module With fiber optic it transmits speed up to 1000 Mbps and you can prevent...

Page 27: ...19 Chapter3 Figure 2 9 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver Figure 2 10 LC connector to the transceiver ...

Page 28: ... follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Figure 2 11 Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Figure 2 12 Pull out from the transceiver ...

Page 29: ...l relay output Figure 2 8 Pin Assignment of the Power Connector You can connect an alarm indicator buzzer or other signaling equipment through the relay output The relay opens if power input 1 2 fails or port link down break Open means if you connect relay output with an LED the light would be off ...

Page 30: ...EKI 7626C User Manual 22 ...

Page 31: ...23 Troubleshooting CHAPTER ...

Page 32: ...t exceed 100 meters 328 feet Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying If the power indicator does not light up when the power cord is plugged in user may have a problem with power cord Then check for loose power connections power losses...

Page 33: ...25 Pin Assignment Wiring APPENDIX ...

Page 34: ...EKI 7626C User Manual 26 Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A ...

Page 35: ...27 Compatible SFP Modules APPENDIX ...

Page 36: ...Brand Part Number Mode Transmission Distance 1 AVAGO AFBR 5710PZ Multi mode 550m 2 APAC LM28 C3S TC N 550m 3 HOATECH HTI8512 X5ATO 550m 4 SPACE SHUTTLE S56L S85 6L N 550m 5 LuminentOIC SP GB LX Single mode 10km SP GB ELX 20km SP GB XD 50km 6 AVAGO AFCT 5710PZ 10km 7 APAC LS38 C3M TC N 20km 8 SPACE SHUTTLE S56L L13 6L N 10km ...