1 Startup Manual 

 

Overview 

The EKI-2528I-M12 unmanaged switches are 
designed for application in harsh environments. First 
of all, the switches provide 8 Fast Ethernet ports with 
M12 D-coded connectors which can connect the 
cables tightly against vibration and shock. Second, 
the switches support 10/100 Mbps, auto MDI/MDI X, 
broadcast storm protection. Third, when supporting 
wide power input ranging from 12 to 48V with 
Polarity Reverse Protection and Overload Current 
Resettable Fuse, the EKI-2528I-M12 switches are 
robust and economical solutions for your network. 
Finally, as the switches are IP67-rated and is 
compliant with IEC 61131-2:2017, they are suitable 
for PLC application and their associated peripherals. 

Packing List

 

Before installation, please make sure that you have 
received the following:   

 

1 x EKI-2528I-M12 Ethernet Switch 

 

1 x Bag of Screws for DIN-rail and Grounding 

 

1 x DIN-rail Mounting Kit 

 

1 x EKI-2528I-M12

 

Startup manual   

If anything is missing or damaged, contact your 
distributor or sales representative immediately. 

 

Notes

For more information on this and other Advantech
products, please visit our websites at:

http://www.advantech.com/products

For technical support and service:

http://www.advantech.com/support/

This startup manual is for EKI-2528I-M12

Part No: 2049252820                                1st Edition

March 2019

 
 

Specifications 

General   

 

Compatibility: 

IEEE 802.3, 802.3u, 802.3x

 

 

LAN: 

10/100Base-TX 

 

Ethernet RJ-45: 

Up to 100 m 

 

Connectors: 

8 x M12 with D-code 
1 x 4-pin M12 A-code for Power Connection 

 

Switch Architecture: 

Store and Forward 

 

Power Requirement:

 12~48V

DC

 redundant dual 

inputs

 

 

Power Consumption: 

2.5 Watts

 

 

Dimensions (W x H x D):

 62 x 194 x 25 mm 

(2.44" x 7.63" x 1.00") 

 

Enclosure:

 IP67

 

 

Operating Temperature:

   

-40 ~ 75 °C (-40 ~ 167 °F)

 

 

Storage Temperature:

   

-40 ~ 85°C (-40°F ~ 185°F) 

 

Operating Humidity: 

5 ~ 95% (non-condensing)

 

 

Storage Humidity: 

5 ~ 95% (non-condensing)

 

 

Safety: 

UL 61010 

 

EMI:

   

EN 61131-2 
CE, CE-LVD, FCC Class A, RCM

 

 

EMS:   

EN 61000-4-2 
EN 61000-4-3 
EN 61000-4-4 
EN 61000-4-5 
EN 61000-4-6 
EN 61000-4-8 
Shock IEC 60068-2-27 
Freefall IEC 60068-2-32

 

 

Vibration IEC 60068-2-6: 

5g @ 10-150Hz

 

 

Warranty:

 5 years 

 