Summary of Contents for EKI-2525M

Page 1: ...EKI 2525M Industrial 5 port Unmanaged Ethernet switch with 1 port 100FX EKI 2526M Industrial 5 port Unmanaged Ethernet switch with 2 port 100FX User Manual ...

Page 2: ...n any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows a...

Page 3: ...placement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer an...

Page 4: ...d can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech...

Page 5: ...nything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service ...

Page 6: ...s from damage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components ...

Page 7: ... EKI 2525M 2526M 9 Figure 2 2 Side View of EKI 2525M 2526M 10 Figure 2 3 Rear View of EKI 2525M 2526M 11 Figure 2 4 Top View of EKI 2525M 2526M 12 2 3 Mounting 13 2 3 1 Wall mounting 13 Figure 2 5 Combine the Metal Mounting Kit 13 2 3 2 DIN rail Mounting 14 Figure 2 6 Installation to DIN rail Step 1 14 Figure 2 7 Installation to DIN rail Step 2 15 2 4 Network Connection 16 Figure 2 8 Pin Assignmen...

Page 8: ...EKI 2525M 2526M User Manual V2 1 051507 viii ...

Page 9: ...1 Chapter1 Overview Sections include Introduction Features Specifications Packing List Safety Precaution CHAPTER ...

Page 10: ... and send an alarm through a relay output for notifying user 1 1 3 Flexible Mounting EKI 2525M 2526M is extremely compact 37 x 140 x 95 mm and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment 1 1 4 Advanced Protection EKI 2525M 2526M supports up to 3 000 VDC surge protection for power line and also supports 4000V ESD for Ethernet ports With these 2 st...

Page 11: ... ports Support full half duplex flow control Supports store forward transmission supports auto negotiation Supports MDI MDI X auto crossover Provides surge protection EFT 3 000 VDC for power line Supports 4 000 VDC ESD protection for Ethernet Supports 12 48 VDC power input Provides flexible mounting DIN rail Wall Mounting Supports operating temperatures from 40 75 wide operating temperature model ...

Page 12: ... 100M fiber EKI 2526M 6 pin removable screw terminal power relay LED Indicators Unit P1 P2 P Fail TX port Link Active Duplex Collision Power Current Overload Protection 0 9A 12VDC 25 Power Consumption EKI 2525M 4 44 W EKI 2526M 6 41 W Power Input 2 x Unregulated 12 48 VDC Fault Output 1 Relay Output Mechanism Dimensions WxHxD 37 x 140 x 95 mm Enclosure IP30 Metal shell with solid mounting kits Mou...

Page 13: ...erature 40 85 Certifications Safety UL 60950 1 CAN CSA C22 2 No 60950 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 5 6 8 11 12 EN61000 6 2 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 ...

Page 14: ...ustrial Communication CD ROM with software and User manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x EKI 2525M 2526M Startup Manual 1 x DC Jack Cable 2 0 150mm 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Page 15: ...7 Chapter2 Installation Sections include LED Indicators Dimensions Mounting Network Connection Power Connection CHAPTER ...

Page 16: ...525M 2526M LED Definition LED Color Description On Power input 1 is active P1 Green Off Power input 1 is inactive On Power input 2 is active P2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive P Fail Red Off Power input 1 and 2 are both active or no power input On Connected to network Flashing Networking is active Link Active 1 5 for EKI 2525M 1 6 for EKI 2526M Green Off Not c...

Page 17: ...9 Chapter2 2 2 Dimensions units mm Figure 2 1 Front View of EKI 2525M 2526M ...

Page 18: ...EKI 2525M 2526M User Manual V2 1 051507 10 Figure 2 2 Side View of EKI 2525M 2526M ...

Page 19: ...11 Chapter2 Figure 2 3 Rear View of EKI 2525M 2526M ...

Page 20: ...EKI 2525M 2526M User Manual V2 1 051507 12 Please refer to page 17 for pin assignment of power connector Figure 2 4 Top View of EKI 2525M 2526M ...

Page 21: ...l mounted by using the included mounting kit Then hang on the EKI 2525M 2526M to the nails on the wall First use the screws included in the package to combine the EKI 2525M 2526M and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below Figure 2 5 Combine the Metal Mounting Kit ...

Page 22: ...y below steps The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 2525M 2526M to the DIN rail with angle of inclination See figure 2 6 Figure 2 6 Installation to DIN rail Step 1 ...

Page 23: ...15 Chapter2 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 ...

Page 24: ... EKI 2525M and EKI 2526M both have 4 x RJ 45 ports that support connection to 10 Mbps Ethernet or 100 Mbps Fast Ethernet and half or full duplex operation EKI 2525M 2526M can be connected to other hubs or switches through a twisted pair straight through the cable or a crossover cable up to 100m long The connection can be made from any TX port of the EKI 2525M 2526M MDI X to another hub or switch e...

Page 25: ... and power fail relay output Figure 2 9 Pin Assignment of the Power Connector You can connect an alarm indicator buzzer or other signaling equipment through the relay output The relay opens if power input 1 or 2 fails Open means if you connect relay output with an LED the light would be off ...

Page 26: ...EKI 2525M 2526M User Manual V2 1 051507 18 ...

Page 27: ...19 Chapter2 Troubleshooting CHAPTER ...

Page 28: ...nection does not exceed 100 meters 328 feet Otherwise use the 50 125 62 5µm fiber cable to connect the fiber port in multi mode 3 Diagnosing LED Indicators The switch can be easily monitored through panel indicators which describes common problems user may encounter and where user can find possible solutions to assist in identifying If the power indicator does not light up when the power cord is p...

Page 29: ...21 Chapter2 Pin Assignment Wiring APPENDIX ...

Page 30: ...5M 2526M User Manual V2 1 051507 22 Appendix A Pin Assignment Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment Figure A 2 EIA TIA 568B Figure A 2 EIA TIA 568A ...