EKI-1360-BE Series User Manual
2.2.4
Network Connection
For RJ45 connectors, data-quality, twisted pair cabling (rated CAT5 or better) is
recommended. The connector bodies on the RJ45 Ethernet ports are metallic and
connected to the GND terminal. For best performance, use shielded cabling.
Shielded cabling may be used to provide further protection.
Figure 2.13 Ethernet Plug & Connector Pin Position
Maximum cable length: 100 meters (328 ft.) for 10/100BaseT.
2.2.5
Serial Connection
EKI-1360-BE Series provides up to four ports DB9 (male) connectors. RS-232/422/
485 pin assignments as below:
Figure 2.14 DB9 Pin Assignment
Straight-thru Cable Wiring
Cross-over Cable Wiring
Pin 1
Pin 1
Pin 1
Pin 3
Pin 2
Pin 2
Pin 2
Pin 6
Pin 3
Pin 3
Pin 3
Pin 1
Pin 6
Pin 6
Pin 6
Pin 2
1
8
Pin
1
2
3
4
5
6
7
8
9
RS-232
DCD
RX
TX
DTR
GND
DSR
RTS
CTS
RI
RS-422
TX-
TX+
GND
RX+
RX-
RS-485
DATA-
DATA+ GND
1
9
6
5