15
ACP-7000 User Manual
Chapter 3
O
peration
3.1.2
LED Indicators for System Status
The LED display on the front door shows a series of indicators that are grouped into
two categories for System Status and Power Voltage Status.
Figure 3.2 Front LED panel
The following table describes the LED indicators for System Status.
When the system power is on, the
PWR LED
is always
Green
. When the
PWR LED
is
RED
, it indicates a redundant power supply module failure. To stop the alarm beep,
press the
Alarm Reset
button. Examine the redundant power supply module right
away and replace the failed module with a good one.
When the
FAN LED
is
RED
, it indicates a failed cooling fan, and the alarm is also
activated. To stop the alarm beep, press the
Alarm Reset
button and then replace
the failed fan with a good one immediately.
If the
TEMP LED
is
RED
, it means that the inside of the chassis has overheated. An
audible alarm will be activated. To stop the alarm beep, press the
Alarm Reset
but-
ton. Inspect the fan filter and the rear section of the chassis immediately. Make sure
the airflow inside the chassis is smooth and not blocked by dust or other particles.
Table 3.1: LED Indicators for System Status
LED
Description
Green
Red
PWR
System power
Normal
Abnormal
HDD
Hard disk drive activity
Data access
No light
TEMP
Temperature in the chassis
Normal
Abnormal
FAN
Cooling fan status
Normal
Abnormal
Summary of Contents for ACP-7000
Page 6: ...ACP 7000 User Manual vi...
Page 10: ...ACP 7000 User Manual x...
Page 14: ...ACP 7000 User Manual 4 1 5 Dimension Diagram Figure 1 1 Dimension diagram Unit mm inch...
Page 36: ...ACP 7000 User Manual 26...
Page 45: ...Appendix A A Exploded Diagram and Parts List...