AWMA-Kx500-BTE
TABLE 12
: COMPUTER TERMINAL COMMANDS FOR RS-232 INTERFACE
Command
Description
Response
h Help
function
Provides the list of commands that can be used to
modify the status of an SSPA.
<ENTER>
ENTER key of keyboard
Provides and refreshes the main menu display on the
computer monitor screen.
alm
Alarms
Displays the ALARMS of the unit (OK if no alarm)
ata
Attenuation on path A
Displays the factory attenuation set on path A
atb
Attenuation on path B
Displays the factory attenuation set on path B
cfg
Configuration
Displays and sets the system configuration mode (ab,
as, or bs) in phase-combined redundant systems
cur
Consumption
Displays the DC current consumption of the unit
dat Date(d:m:y)
Current date will be displayed (in format day :
month : year)
elt Elapsed
Time
Elapsed functioning time
fpw
Forward Power
Displays the forward transmission output power (in
dBm)
ltr Low
power
threshold
Low power ALARM threshold set and display
mac
MAC address
Displays the Monitor and Control address
nam
Set unit name
Allows for a name to be attributed to the unit
psn
Unit position
Displays the position of the unit in the system (A, B,
or S) – for redundant systems only
red
Redundancy Mode
Allows for the setting of redundancy mode (auto or
manual)
rpw
Reflected Power
Displays the reflected transmission power (in dBm).
rst
Reset
Fault reset (resets the controller of the unit after a
Fault condition (if the condition was removed)
38