background image

VSX41 

Video Switcher 

 

Operation Manual 

®

 

Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A.    (503) 641-7287    http://www.biamp.com 

an affiliate of Rauland-Borg Corp.

 

Summary of Contents for VSX41

Page 1: ...VSX41 Video Switcher Operation Manual Biamp Systems 10074 S W Arctic Drive Beaverton Oregon 97005 U S A 503 641 7287 http www biamp com an affiliate of Rauland Borg Corp ...

Page 2: ...print update Dec 9 99 blank ...

Page 3: ...tall and carries a five year warranty VSX41 features include four video inputs each with both BNC and RCA connectors one video output with both BNC and RCA connectors front panel push buttons select from the four input sources front panel infrared receiver for remote control of switching two rear panel ports for infrared and or wall mount controls remote output for control of other ADVANTAGE produ...

Page 4: ... see Remote Control on page 4 5 Errors in transmission reception of remote control commands or improperly connected controls will cause the Error indicator to light 3 IR This red LED indicates when information is received via remote control If the IR and Error indicators light simultaneously this may be an indication of improper installation Check the location and wiring of all remote controls 4 I...

Page 5: ...n utilized as the four possible outputs see Applications on page 9 3 Remote 1 Remote 2 These screw terminals are for connection of optional remote controls see Remote Control on pages 4 5 Including the Internal Infrared Receiver the Remote Translator 4 and the Logic Inputs 6 these terminals allow remote control from up to five locations Optional remote controls may be wired up to 2000 feet from th...

Page 6: ... For best results there should be an unobstructed line of sight from transmitter to receiver The receiver may be wired up to 2000 feet from the VSX41 using 2 conductor shielded cable not included Route the cable through the access hole on the bottom of the receiver The three screw terminals inside the receiver GND IR2 IR3 directly correspond to the Remote 1 and Remote 2 terminals on rear panel of ...

Page 7: ...he Logic Input to a high or low state Multiple logic outputs or contact closures may be wired in parallel to a single Logic Input Logic outputs and contact closures should be rated for at least 5 Volt 1 mA operation Low current dry contact closures are recommended for reliability Active output driver circuits should not exceed a signal range of 15VDC to 15VDC and should have a minimum pulse width ...

Page 8: ...nal Infrared Receiver to be bypassed To bypass the Internal Infrared Receiver move the INTERNAL RECV jumper strap J3 left one pin to the OUT position see diagram below J3 IR1 INTERNAL RECV OUT IN ON IR ERROR Logic Inputs Pin Assignments When controlling the VSX41 via logic outputs from an ADVANTAGE AGII or DRC4 4 internal jumpers allow VSX41 Logic Inputs to be assigned to corresponding pins for th...

Page 9: ...IN LEVEL SPM412e Controller CHANNEL SELECT 1 2 3 4 max min MUTE 1 2 3 4 CHANNEL SELECT MUTE VOL VOL MAIN LEVEL ADVANTAGE SPM412e inputs audio sources satellite VCR cable misc This diagram shows a VSX41 used for video source selection in a sports bar application A similar system could be used for classroom applications The VSX41 Remote Output is connected to an ADVANTAGE SPM412e Remote input allowi...

Page 10: ...ortland Oregon an affiliate of Rauland Borg Corp input 4 input 3 input 2 input 1 remote output VSX41 autoONE audio feed to codec video feed to codec presentation camera priority 1 member mics priority 3 chairman camera priority 2 member camera priority 3 room camera priority 4 p r e s e n t a t i o n m i c p r i o r i t y 1 c h a i r m a n m i c p r i o r i t y 1 VOICECRAFTER video feed from codec...

Page 11: ...nal min max 40 20 min max direct xfmr chime level send return auto mute compressor amp in pre out line out rec out remote level stacking in 4 com 8 25V 50V 70V 115 230V AC 50 60 Hz 375 VA 3A 230V BIAMP SYSTEMS an affiliate of Rauland Borg Corp 6A 115V threshold adjust tel phantom pwr auto mute manual mute mute level 40 20 priority line mic on off PRECEDENCE is a registered trademark of Rauland Bor...

Page 12: ...imum input voltage 15VDC switching threshold 2VDC input voltage when idle high input high 2VDC input voltage when idle low input low 2VDC Crosstalk 20Hz 20kHz 70dB Power Requirements 120 240VAC 50 60Hz Power Consumption 8 watts max Dimensions height 1 rack space 1 75 inches 44mm width 19 inches 483mm depth 4 inches 102mm Weight 4 5 lbs 2 04kg ...

Page 13: ... receiver remote 1 remote 2 remote translator signal translator remote output microprocessor 2 3 4 channel select switches 1 2 3 4 output RCA BNC input 1 RCA BNC input 2 RCA BNC input 3 RCA BNC input 4 RCA BNC 3 9kΩ 75Ω relay 2 3 9kΩ 75Ω relay 3 3 9kΩ 75Ω relay 4 relay 1 3 9kΩ 75Ω ...

Page 14: ... fans electrolytic capacitors and the normal wear and tear of appearance items such as paint knobs handles and covers are not covered under this warranty 4 BIAMP SYSTEMS SHALL NOT IN ANY EVENT BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING LOST PROFITS LOSS OF USE PROPERTY DAMAGE INJURY TO GOODWILL OR OTHER ECONOMIC LOSS OF ANY SORT EXCEPT AS EXPRESSLY PROVIDED HEREIN BIAMP SY...

Page 15: ......

Page 16: ......

Page 17: ......

Reviews: