1. This unit is designed to be used with water as the circulating fluid. The quality of 

fluid used in your temperature control unit will greatly effect its short and long-

term operation. Lack of as well as improper water treatment can damage the 

temperature control unit by causing scale build-up, excessive corrosion and/or 

bacterial contamination. It is the equipment owner’s responsibility to prevent damage 

caused by poor water quality. The services of a water treatment professional is 

recommended.

2. Before installing and operating the unit, be aware of and follow any local laws and 

codes that apply to the installation.

3. When contacting the Service Department always have the unit Model and Serial 

number from the data tag located on the side of the unit.

 SERVICE DEPARTMENT: 317-887-0729

*Reference the manual for requirements for 250°F set point.

Before Installing or Operating

Maximum Setpoint

250°F

*

This reference guide covers standard Advantage temperature 

control units with the T Control Instrument. This guide may be 

used for customized units using the T Control Instrument even 

when the unit may not be physically the same as the units 

depicted in the included photos.

Download and read the manual before starting installation. The complete 

manual is available online at www.advantageengineering.com/Sentra-SRV.

Sentra SR Series with V Control Instrument

REFERENCE GUIDE

INSTALLATION • OPERATION • TROUBLESHOOTING

Summary of Contents for Sentra SR Series

Page 1: ...e installation 3 When contacting the Service Department always have the unit Model and Serial number from the data tag located on the side of the unit SERVICE DEPARTMENT 317 887 0729 Reference the manual for requirements for 250 F set point Before Installing or Operating Maximum Setpoint 250 F This reference guide covers standard Advantage temperature control units with the T Control Instrument Th...

Page 2: ...Water In port on the process manifold 4 Connect From Process port to the Water Out port on the process manifold 5 Please note Process water piping circuitry should be designed to avoid an excessive use of elbows and or lengths of pipe or hose If hose is the material of choice avoid tight twists or curls and excessive lengths 6 Valves and filters may be installed in the process water piping circuit...

Page 3: ...temperature limit faults A no FLO indication is displayed Correction of the fault must be corrected prior to operation 4 The instrument controller features an temperature display screen four indicating lights and toggle switch 5 Determine that the pump is rotating in a clockwise direction when viewed from the rear of the motor Follow the instructions in Section 3 2 of the factory operations manual...

Page 4: ...ctive PVTTM cooling valve 2 Heater element failure 3 Process heating requirement exceeds unit heating capability 4 Control instrument defective and not calling for heat Pressure Relief Valve Leaks 1 Water supply pressure too high See manual 2 Pressure relief valve contamination Basic Troubleshooting is shown here Refer to the Manual for full information Continued On Off Switch Engages disengages t...