Manual

Series 75 

Controller

Installation

Maintenance

Repair

Manual

Advantage Controls

4700 Harold-Abitz Dr.

Muskogee, OK  74403

Phone: 800-743-7431

Fax: 888-686-6212

www.advantagecontrols.com

email: [email protected]

01/2021

Summary of Contents for 75 Series

Page 1: ... 75 Controller Installation Maintenance Repair Manual Advantage Controls 4700 Harold Abitz Dr Muskogee OK 74403 Phone 800 743 7431 Fax 888 686 6212 www advantagecontrols com email support advantagecontrols com 01 2021 ...

Page 2: ...2 Series 100 Controller Manual Table of Contents Contents Page I Introduction 3 II Installation 3 Quick Connect Terminal Wiring 4 III System Operation 5 IV Warranty and Factory Service Policies 6 ...

Page 3: ...ate necessary wiring to the Quick Connect terminals as required See diagram on page 4 Each terminal is labeled for the proper connection Terminals P1 P9 are high voltage for power motor inlet and flush solenoid Utilize proper 3 conductor wire size for the appliance WARNING The controller is rated for maximum 20 amp total load Terminal strip P11 is dry contact for input signals from tank full press...

Page 4: ...not shared Any attempt to bypass the grounding will compromise the safety of users and property 6 The electrical installation of the controller must be performed by trained personnel only and conform to all applicable National State and Local codes 7 Operation of this product in a manner not specified by the manufacturer may result in damage to equipment or persons 8 Avoid mounting in locations th...

Page 5: ...d the RO will not restart until the Power Switch has been manually cycled OFF then ON to reset the unit If switch 1 is in the ON Position auto reset every 60 minutes the RO will start and stop again if a pressure fault continues If switch 2 is in the ON Position pressure fault retry the RO will attempt to restart after 30 seconds then 5 minutes then 30 minutes If the pressure alarm has not cleared...

Page 6: ... purchaser of its products whether in contract or in tort and whether arising out of warranties representations instructions installations or defects from any cause will be limited exclusively to repairing or replacing the product or any part thereof under the conditions set out above 30 Day Billing Memo Policy Advantage Controls maintains a unique factory exchange program to ensure uninterrupted ...

Page 7: ...ollers Boiler Blow Down Controllers Blow Down Valve Packages Solenoid Valves Water Meters Chemical Metering Pumps Corrosion Coupon Racks Chemical Solution Tanks Solid Feed Systems Feed Timers Filter Equipment Glycol Feed Systems Pre Fabricated Systems Get the Advantage 5 4 3 2 1 0 9 8 7 6 BACK HOME HELP ENTER CANCEL SET UP RUN 5 4 3 2 1 ENTER HELP 5 4 3 CHANGE RUN SET UP 0 9 8 2 1 7 6 HOME BACK ...