2.3
Cable Connections
The cable connections for a typical dispensing system are illustrated below. To assure
proper connections, each of the component cables supplied by Advanjet has a distinct
connector. Be sure that all power is off when connecting and disconnecting any cable to
the Advanjet controller.
Jet:
A 28-pin cable (P/N 06-1095-00) mates with the HV-2100 jet cable to connect it to
the HV-2100C controller. Section 2.4 provides HV-2100 Jet Cable pin assignments.
I/O:
When using the HV-2100 jet with the HV-2100C controller and a robot, six TTL
trigger lines control jet operations through a 26-pin cable (P/N CB26-005).
COMM:
A PC can be connected to the controller via RS-232C/USB to operate the
HV-2100 using software instead of the front panel touch screen.
Figure 2-3: Cable Connections for the HV-2100 in a Typical Dispensing System
3A6244A
Advanjet HV-2100 Jet Setup and Operation
Page 9 of 22