Advanced HBC-3130 User Manual Download Page 7

K. Trouble Shooting

PROBLEM

INDICATIONS

POSSIBLE CAUSES

SUGGESTED SOLUTION

Charger does not
work 

Indicator lights not
turn on 

No AC power

AC input socket fuse blown 

Check AC connections are correct 

Replace with correct AC fuse by qualified
electrician

No DC output 

Charger - On LED is
not on, Float and
Fault LEDs are on

Output short circuit 

Over temperature protection triggered 

Severe over loading charger

Reverse polarity connection

DC fan locked by foreign object or
malfunction

Check DC connections between charger
and battery. Charger can auto reset if
remove the fault within 20 seconds.

Check air intake vent at bottom of charger
is blocked or not. Check charger ambient
ventilation .

Check battery AH capacity within
recommended range

Check for correct polarity, replace car
blade fuse (6)

Check DC fan

Battery does not get
full charge

All indicator LED
work normally and
sequentially 

OTP LED flashing

Bad battery connection 

Battery type select switch in wrong setting

Battery capacity too large

Ambient temperature too low 

Battery has damaged cell or battery is too
old 

Wrong set the lower power level

Check for loose contact, right cable size,
cable integrity

Recheck battery type and change to
correct battery selection

Make sure charger rating matches battery
capacity see table

 

(B2)

Move battery to a room temperature
location, or get an optional temperature
sensor 

Replace battery

Recheck the current selection switch (5) to
correct right setting

Long charging
time , float light
does not come on
even after 12 hours
charging time.

Absorption light
remains on all the
time 

Charger internal fault 

Return the charger to distributor to repair 

Bulk LED is on all
the time 

Bulk light remains
on all the time 

Wrong battery type selection

Battery is excessively depleted and the
soft charging is triggered  

Battery temperature too high

Check charged battery label and change
battery type selection to correct setting

Recharge the battery after a day, if bulk
light remains after several hours, the
battery is most likely damaged and cannot
accept charge. Replace battery.

Use accessory temperature sensor

Summary of Contents for HBC-3130

Page 1: ...charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face away w...

Page 2: ...er programmable charging profiles for the professional users through USB port by personal computer In addition the programmed maintenance charge provides a timely Equalization charge for the Wet lead...

Page 3: ...h fuse holder 12 Temperature Sensor Socket Connection to optional accessory temperature sensor Sensor to increase decrease charging voltage at low high battery temperature B Battery Type Selection Mak...

Page 4: ...ion and then the battery connection Please notice the tightness of the power cables from the power supply to the load If the cables are not fastened well enough the total resistance of the connecting...

Page 5: ...avans and vehicles with two separate batteries The two batteries must be of same chemical make up and type to avoid over and under charging because only one setting of charging profile for both Two ba...

Page 6: ...um one way distance feet for 2 Voltage loss 40A Maximum one way distance feet for 2 Voltage loss 60A 10 5 26 3 8 2 8 1 6 8 8 37 6 4 5 2 5 6 13 3 9 5 7 2 3 6 4 21 2 15 11 2 6 8 2 33 6 24 18 11 1 0 53 5...

Page 7: ...witch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable size ca...

Page 8: ...rotection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Re...

Page 9: ...coupler HBR 3100 accessories II Connection 1 10 Meters Phone Cable 2 In Line Coupler 6P6C 3 HBR 3100 Remote Display Module III Control and Indicator 1 Output ON OFF To switch the charger output ON and...

Page 10: ...Time Display units total run time 9 Output Power Level Display current output level 10 Software Version Displays the current control software version Remote Short cut 1 Press and hold the SET button...

Page 11: ...g Systems This software is compatible with 32 bit computer and operating systems of Win Vista XP and Win 7 Installing the USB Driver 1 1 CD USB Drivers for Win_2K_XP_S2K3_Vista CP210xVCPInstaller exe...

Page 12: ...USB Driver has been successfully installed 2 Installing the HBC Charge Program 2 1 Double click on CD setup exe 2 2 Follow the steps as shown in the following windows it may take a few minutes to inst...

Page 13: ......

Page 14: ...2 Select a COM Port number that matches the USB com port number 3 3 You can find your USB Com number from your device manager as shown in window at section1 4 In this example is Com 3 for the USB Com...

Page 15: ...a If the configuration is successful connection OK will appear b If configuration fails No Connection will appear 3 6 Trouble shooting for No Connection...

Page 16: ...o download accumulative run time of the charger since the first operation the Output charging voltage and current values at 10 minute intervals the voltage at each of the two battery terminals are als...

Page 17: ...7 2 Profile General setting Nominal bat Voltage select 12V or 24 V battery Nominal bat Capacity Key in the battery bank AH Click OK to confirm save settings 3 7 3 Profile Protection conditions settin...

Page 18: ...ng stage that can be used each has its own charging voltage and current limit 3 7 5 Profile Charge Stage change to next stage condition These are the available threshold parameters that cause shift of...

Page 19: ...3 7 6 Profile Conditions for Jumping from one Stage to any other Stage Non sequential change of stage selection and condition windows...

Page 20: ...minute interval When the data bank is full new data will push the oldest out Each set of data is marked with a number new set of data has the highest number 3 8 1 Get Data Total Run Time This drop wi...

Page 21: ...all the data from record 1 which is the oldest one to the most recent one Chr volt charging voltage Curr charging current bat 1 volt voltage at battery terminal 1 bat 2 volt voltage at battery termina...

Page 22: ...ing the Data Log Graph When you open the data log you saved by this software the following graph will appear Voltage Blue color Current red color WH Watt hour with 30 deducted adjustment for energy ch...