COOLING SPECIFICATIONS
Table 10‑5. Cooling specifications
Description
Specification for 600 Series
Specification for 1000 Series
Cooling method
Natural convection
ENVIRONMENTAL SPECIFICATIONS
Table 10‑6. Environmental specifications
Equipment
Status
Model
Temperature
Air Pressure
Operating range
All models
–25°C to +55°C (–13°F to +131°F)
Up to 2000 m
(6562′) without
power de-rating
Full power range
AE 3TL-12kW
AE 3TL-16kW
AE 3TL-20kW
AE 3TL-23kW
–25°C to +50°C (–13°F to +122°F)
–25°C to +50°C (–13°F to +122°F)
–25°C to +45°C (–13°F to +113°F)
–25°C to +40°C (–13°F to +104°F)
Standby/Storage
range
All models
–30°C to +70°C (–22°F to +158°F)
NOISE EMISSIONS
Noise emissions: < 45 dBA at 16.5′
Advanced Energy® AE 3TL Inverters