6.2.1. CCID Bulk-OUT Messages
6.2.1.1.
PC_to_RDR_IccPowerOn
This command activates the card slot and returns ATR from the card.
Offset
Field
Size
Value
Description
0
bMessageType
1
62h
-
1
dwLength
4
00000000h
Size of extra bytes of this message
5
bSlot
1
-
Identifies the slot number for this
command
6
bSeq
1
-
Sequence number for command
7
bPowerSelect
1
-
Voltage that is applied to the ICC:
00h = Automatic Voltage Selection
01h = 5 V
02h = 3 V
8
abRFU
2
-
Reserved for future use
The response to this command message is
RDR_to_PC_DataBlock
response message and the data
returned is the Answer-to-Reset (ATR) data.
6.2.1.2.
PC_to_RDR_IccPowerOff
This command deactivates the card slot.
Offset
Field
Size
Value
Description
0
bMessageType
1
63h
-
1
dwLength
4
00000000h
Size of extra bytes of this message
5
bSlot
1
-
Identifies the slot number for this
command
6
bSeq
1
-
Sequence number for command
7
abRFU
3
-
Reserved for future use
The response to this message is the
RDR_to_PC_SlotStatus
message.
6.2.1.3.
PC_to_RDR_GetSlotStatus
This command gets the current status of the slot.
Offset
Field
Size
Value
Description
0
bMessageType
1
65h
-
1
dwLength
4
00000000h
Size of extra bytes of this message
5
bSlot
1
-
Identifies the slot number for this
command
6
bSeq
1
-
Sequence number for command
7
abRFU
3
-
Reserved for future use
The response to this message is the
RDR_to_PC_SlotStatus
message.