Service Manual – Advance 7765 / Nilfisk CR1500
Scrub System Hydraulic Diagrams
Scrub Brush Motors Off
When the
Scrub Brush Motors
are off, the
Normal Rotation Brush (4)
solenoid is de-energized (open). This allows
the hydraulic oil to flow from the
Auxiliary Pump
, through non-priority leg of the priority flow divider and
through the
Normal Rotation Brush (4)
solenoid valve.
• If the Main Broom Switch is off, the
Main Broom Solenoid (2)
is de-energized (open). The oil will flow
through the
Main Broom Solenoid (2)
valve and
Normal Rotation Brush (4)
solenoid valve, then go to the
Hopper Control Valve
.
To Side
Broom Valve
Scrub Brush
Motors
10.0
CIR
10.0
CIR
0.34
CIR
4.50
CIR
10.0
CIR
.75
GPM
Main Control
Valve
Dust
Control
Motor
Main
Broom
Motor
P
P1
1
2
3
T
4
1.02
CIR
1.24 CIR
Return Block
Reservoir
Drive
and
Auxiliary
Pump
To Hopper
Control Valve
9.7 GPM
T1
Main Broom
Solenoid (2)
Normal Rotation
Brush (4)
Reverse
Rotation
Brush (3)
Summary of Contents for 56514925
Page 28: ...General Information 28 Service Manual Advance 7765 Nilfisk CR1500 Maintenance Item Locations ...
Page 74: ...Engine System common Electrical System 74 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 89: ...Engine System Diesel 89 Service Manual Advance 7765 Nilfisk CR1500 Starter Relay ...
Page 113: ...Engine System Gasoline LPG 113 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 114: ...Engine System Gasoline LPG 114 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 115: ...Engine System Gasoline LPG 115 Service Manual Advance 7765 Nilfisk CR1500 ...