Step 10 Detach the wrist strap from your wrist, disconnect the earthing cable
from the ESD grounding point on the shelf (if available) or the rack
and lay the earthing cable aside.
If you have any problems that result in a deviation from the connect-
ing procedure described above, contact ADVA Optical Networkingís
Technical Support. See the Preface for contact details.
End of Procedure
Connecting the 40CSM/2HU Shelf to a FSP
3000R7 Shelf
This section describes how to connect a 40CSM/2HU Shelf to a management
controller installed in a FSP 3000R7 Shelf.
Unless otherwise specified below, the term 40CSM/2HU Shelf always refers to
the following shelf types:
•
40CSM/2HU-#D02-#D32
•
40CSM/2HU-#D34-#D64
•
40CSM/2HU-#19590-#19200
•
40CSM-FL/2HU-#19590-#19200
•
40CSM/2HU-#19595-#19205
•
40CSM-C80/2HU-#19590-#19200
•
40CSM-C80/2HU-#19595-#19205
•
40CSM/P-2HU-#19590-#19200-DM
To supply the 40CSM/2HU Shelf with power and to provide management func-
tionality, you have to connect it to a management controller such as the Passive
Shelf Control Unit (PSCU) or the Common Equipment Module (CEM/9HU). The
PSCU may be installed in a SH9HU, SH7HU or SH1HU shelf. The CEM/9HU is
included in the SH9HU only. Management functionality is restricted to inidicate
the filter shelf in each of the management tools.
CAUTION
Only Service Personnel are allowed to perform this procedure.
Ensure that you are grounded with a wrist strap or equivalent while
connecting the cable.