Removing and Inserting a Dummy Module
256
Installation and Commissioning Manual
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Step 7
Detach the wrist strap from your wrist, disconnect the grounding wire
from the ESD grounding point on the shelf (if available) or the rack
and lay the grounding wire aside.
Step 8
Store the box or container with the dummy module in a safe place for
future use.
End of Procedure
Inserting a Dummy Module
Equipment Required
Before starting the procedure, ensure the following is available.
•
Appropriate dummy module packaged in the shipping box
•
ESD-preventive wrist strap or other personal grounding device
Insertion Procedure
It is assumed that you are familiar with optical modules, and are aware of the
precautions that should be taken to avoid damage to the equipment.
Follow these steps to insert a dummy module into a shelf slot.
Procedure
Step 1
Attach a wrist strap to your bare wrist and fasten the grounding wire
onto the ESD grounding point on the shelf (if available) or to a bare
metal surface onto the rack.
Step 2
Find the empty slot within the shelf which is to be populated with the
dummy module.
CAUTION
Only Service Personnel or suitably qualified personnel are allowed to
perform this procedure.
To prevent ESD damage to adjacent optical modules, take normal
static precautions in inserting dummy module.