Chapter 5 Installing Shelves
Installation and Commissioning Manual
131
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Figure 11:
Fitting the ETSI and NEBS Adapter Brackets to an 9HU shelf
b) Reinsert the three fixing screws into the threaded holes.
c) Secure the bracket to the shelf by tightening the screws with a
Torx screwdriver TX20.
Step 10 Save the 19-inch bracket with the packaging material.
Step 11 Repeat steps 1 to 10 of this procedure for the opposite side.
Reattach the front cover by pressing the outer black latches and releasing them
onto the fixing brackets if there is nothing else to be done.
End of Procedure
Fitting a 7HU Shelf with ETSI or NEBS Brackets
This subsection describes the procedure that must be followed in order to fit the
SH7HU and SH7HU-R (in the following referred to as 7HU Shelf) with ETSI or
NEBS brackets. ETSI brackets are required to adapt the 7HU Shelf to the ETSI
standard rack dimensions. NEBS brackets are required to adapt the 7HU Shelf
to the NEBS standard rack dimensions.
ETSI bracket
NEBS bracket
19-inch bracket
19-inch bracket
ETSI bracket
NEBS bracket
Front cover
fixing brackets
CAUTION
Only Service Personnel are allowed to replace the 19-inch brackets
with the ETSI or NEBS brackets.