background image

1

TRACER Monitored Protection Switch (MPS)

Before you begin...

 

Required Components

(2) TRACER Baseband Processor (BBP) and RF Converter (RFC) rackmount units

Or,

(2) TRACER 4103 or 4203 integrated rackmount radio units

RS-232 interface cable and VT100 terminal (or a PC with VT100 emulator software) for connecting to the unit

(2) RS-232 (MALE) to RJ-45 (FEMALE) adapter (ADTRAN P/N 3196ADPT010) for creating the VT100 management chain (included in 
the TRACER MPS shipment)

(2) 8-conductor RJ-45 to RJ-45 straight-through cable for creating the VT100 management chain (included in the TRACER MPS 
shipment)

(4) Straight-through T1 cables to connect the TRACER BBP or 4103/4203 T1 interfaces to the MPS (2 are included in each TRACER 
shipment) 

(2) N-Type (MALE) to SMA (MALE) cables for connecting the antenna interfaces (TRACER units) to the TRACER MPS (included in the 
TRACER MPS shipment)

18, 20, or 22 AWG dual-conductor cable for connecting the alarm contacts between the TRACER BBP or 4103/4203 and the TRACER 
MPS; also needed for connecting the MPS to an external alarm monitoring system

Antenna, mounting hardware, and feedline cable

21 to 63 VDC power source (available from ADTRAN)

(2) Straight-through T1cables  to connect the TRACER MPS to other CPE equipment (included in the TRACER MPS shipment)

Or,

(2) T1 crossover cables to connect the TRACER MPS T1 interfaces to the public-switched network (included in the TRACER MPS 
shipment)

About this Quick Start Guide...

This guide contains information for installing your TRACER MPS system. ADTRAN recommends that the entire TRACER link be tested on a 
lab bench prior to installation in the field.

Verify the existence of an adequate microwave path for each hop or link to ensure that a point-to-point microwave system is feasible for your 
particular application. Record the frequency of your microwave system (2.4 GHz or 5.8 GHz) and be sure to configure the Frequency Band 
menu option appropriately before operating your TRACER MPS. For more details, refer to Reviewing the Menus on page 4.

Quick Start Guide

61280300L1-13B

October 2003

Summary of Contents for TRACER Protection Switch

Page 1: ...acts between the TRACER BBP or 4103 4203 and the TRACER MPS also needed for connecting the MPS to an external alarm monitoring system Antenna mounting hardware and feedline cable 21 to 63 VDC power so...

Page 2: ...below each BBP T R A C E R MAIN STANDBY OUT NO COM NC MN COM SB IN ALARMS DC POWER RF ANTENNA TO DTE RS 232 MONITOR T1B T1A MAIN TRACER STANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONLY M...

Page 3: ...OR T1B T1A MAIN TRACER STANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONLY OUT IN IN OUT B A B A MAIN STAND BY MANAGEMENT T1A T1B STANDBY UNIT VT100 Connection MAIN UNIT VT100 Connection 1...

Page 4: ...tatus parameters 5 Activates the menu system for the STANDBY TRACER unit This provides access to all configuration and status parameters 6 Configures the TRACER MPS for modem or terminal access When c...

Page 5: ...s labeled 3 and 4 below 2 Repeat Step 1 to connect the T1A and T1B interfaces of the STANDBY TRACER BBP to the STANDBY T1A and T1B interfaces RJ 45 of the TRACER MPS labeled 5 below MAIN UNIT T1B Inte...

Page 6: ...labeled 1 below to the MAIN RF interface SMA con nector of the TRACER MPS labeled 2 below using a male N Type to male SMA cable 2 Connect the IF connector on the MAIN TRACER BBP labeled 4 below to th...

Page 7: ...3 below T R A C E R MAIN STANDBY OUT NO COM NC MN COM SB IN ALARMS DC POWER RF ANTENNA TO DTE RS 232 MONITOR T1B T1A MAIN TRACER STANDBY TRACER MONITOR POWER MODULE USE COPPER CONDUCTORS ONLY OUT IN...

Page 8: ...ovides the optional MIN Minor Alarm terminal block Connecting the MIN alarm contacts allows the TRACER MPS to perform a system switch when a minor alarm condition occurs Please refer to the TRACER 260...

Page 9: ...e applied voltage in Volts As an example at 48 Volts the TRACER MPS would draw approximately 0 417 Amps peak 20 Watts 48 Volts 9 Pinouts MAIN STANDBY T1A T1B INTERFACES RJ 45 Pin Name Description 1 R...