background image

T200 H4R

JOB

A

ID

T200 H4R

CLEI: T1R6TJZD_ _

1222441L1

PWR

H   R

LP1

NET

LP2

LP1

LP2

LL  RL
(Y)  (G)

/

CUST

61222441L1-22A

0211

LOOPBACK AND CONTROL CODES

Refer to the H4TU-C or H4TU-R Installation and Maintenance Practice for a list of
loopback codes.

CARD EDGE PIN ASSIGNMENTS

COMPLIANCE

This product is intended for installation in restricted access locations only and in
equipment with a Type “B” or “E” enclosure.

WARNING: Up to -200 VDC might be present on telecommunications wiring. Ensure

chassis ground is properly connected.

This product provides span powering voltage (negative only with respect to ground, 
-190 VDC nominal, GFI protection < 5 mA) and meets all requirements of Bellcore
GR-1089-CORE (Class A2), ANSI T1.418-2002.   This product is NRTL Listed to the
applicable UL standards.

■  

For a complete Installation and Maintenance Practice (P/N 61222441L1-5): (877) 457-5007, Faxback Document 874.  Please have your fax number ready.  

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

LED STATUS

PWR

Off 

No span power is present

On

Span power is present

LP1/LP2 NET

Solid Green

Synchronized with an SNR margin greater than the user defined SNR 
Margin Alarm Threshold

Fast Blinking (Blinking three times per second) Attempting to synchronize with the 
Green

H4TU-C

Slow Blinking (Blinking one time per second) Synchronized with an SNR margin 
Green

greater than the user defined SNR Margin Alarm Threshold and the 
pulse attenuation is greater than the user defined Loop Attenuation 
Alarm Threshold

Solid Yellow

Synchronized with an SNR margin greater than 0 dB but less than 
the user defined SNR Margin Alarm Threshold

Slow Blinking Synchronized with an SNR margin greater than 0 dB but less than the 
Yellow

user defined SNR Margin Alarm  Threshold and the pulse attenuation 
is greater than the user defined Loop Attenuation Alarm Threshold

Solid Red

Synchronized with an SNR margin of 0 dB

Slow Blinking (Blinking one time per second) Synchronized with an SNR margin of 
Red

0 dB and the pulse attenuation is greater than the user defined Loop 
Attenuation Alarm Threshold

LP1/LP2 CUST

Solid Green 

Synchronized with an SNR margin greater than the user defined SNR 
Margin Alarm Threshold

Fast Blinking (Blinking three times per second) Attempting to synchronize with the
Green

H4TU-R

Slow Blinking (Blinking one time per second) Synchronized with an SNR margin 
Green

greater than the user defined SNR Margin Alarm Threshold and the 
pulse attenuation is greater than the user defined Loop Attenuation 
Alarm Threshold

Solid Yellow 

Synchronized with an SNR margin greater than 0 dB but less than the 
user defined SNR Margin Alarm Threshold

Slow Blinking Synchronized with an SNR margin greater than 0 dB but less than the 
Yellow

user defined SNR Margin Alarm  Threshold and the pulse attenuation 
is greater than the user defined Loop Attenuation Alarm Threshold

Solid Red 

Synchronized with an SNR margin of 0 dB

Slow Blinking (Blinking one time per second) Synchronized with an SNR margin of  
Red

0 dB and the pulse attenuation is greater than the user defined Loop 
Attenuation Alarm Threshold

LL/RL

Green 

Indicates a loopback at the H4R toward the H4TU-R is active

Yellow 

Indicates a loopback at the H4R toward the H4TU-C is active

Slow Blinking H4R is armed, but not in loopback 
Yellow

Pin No.

Description

1

Chassis Ground

5

HDSL4 Loop Tip (Customer)

7

HDSL4 Loop Tip (Network)

11

Chassis Ground

13

HDSL4 Loop Ring (Network)

15

HDSL4 Loop Ring (Customer)

17

-48 VDC Return (Ground)

27

Chassis Ground

41

HDSL4 Loop Tip (Network)

47

HDSL4 Loop Ring (Network)

49

HDSL4 Loop Ring (Customer)

55

HDSL4 Loop Tip (Customer)

Code

Input Output

Power Code (PC)

C

C

Telecommunication Code (TC)

X

X

Installation Code (IC)

A

#61222441L1-22A#