Quick Start Guide, 61202843L1-13B, July 2005
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Copyright © 2005 ADTRAN, All Rights Reserved
For more detailed documentation, visit us online at
.
Quick Start Guide
®
NetVanta Octal T1/E1 Wide Module
P/N 1202843L1
S
PECIFICATIONS
Operating Modes
Frame Relay, Multilink Frame Relay, PPP, Multilink PPP, HDLC
8xT1 Interfaces
Supported Standards: AT&T TR 62411, AT&T TR 54016, Bellcore TR 194,
ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Codes: AMI or B8ZS
Framing: D4 (SF) or ESF
Input Signal: 0 to -36 dB (DS1); Support for Nx64 on all T1 interfaces
(1 through 8)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft (short)
Connector: RJ-48C
8xE1 Interfaces
Supported Standards: ITU-T G.703, ITU-T G.704 (CRC-4), ITU-T G.823,
ITU-T G.797
Line Rate: 2.048 Mbps ±50 PPM
Line Codes: AMI or HDB3
Framing: FAS/NFAS with optional CRC-4
Input Signal: 0 to -30 dB (DS1) on all E1 interfaces (1 through 8)
FE1 Line Rate: Channelized timeslot (in multiples of 64 kbps)
Connector: RJ-48C
Clock Source
Network, internal
Diagnostics
Network Loopbacks: Line, payload, remote (T1 only)
Test Pattern Generation and Detection: QRSS, 2
15
- 1, 2
20
- 1, 511, all
ones, all zeros
Compliance
FCC Part 15 Class A, EN 55022 Class A, EN 55024, EN 61000-3-2,
EN 61000-3-3
AS/ACIF S016, ETSI TBR 12/TBR 13, ACTA/FCC Part 68, IC CS-03
UL/CUL 60950, EN 60950, IEC 60950, AS/NZS 60950
Physical
Dimensions: 5.63-inch W x 8.63-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
I
NSTALLATION
I
NSTRUCTIONS
1.
Remove power from the unit.
2.
Remove the cover plate from the
wide option slot.
3.
The NetVanta T1/E1 Wide Module
is shipped with the T1/E1 mode
switch (located on the circuit board)
set to T1 (switch set to 1). If you
require E1 functionality, using your
thumbnail, slide the switch to the
ON
position as shown in the bottom
figure to the right.
4.
Slide the wide module into the wide option slot until the module is firmly seated against
the chassis.
5.
Secure the screws at both edges of the module.
6.
Connect the cables to the associated device(s).
7.
Complete the installation of the base unit.
8.
Restore power to the unit.
T1/E1 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUTS
Pin
Name
Description
1
R1
Receive data from the network - Ring 1
2
T1
Receive data from the network - Tip 1
3
—
Unused
4
R
Transmit data toward the network - Ring
5
T
Transmit data toward the network - Tip
6-8
—
Unused
Important:
For additional details on product features, specifications,
installation, and safety, refer to the appropriate Hardware Installation
Guide on the
ADTRAN OS System Documentation
CD shipped with the
base unit and available online at www.adtran.com.