![ADTRAN NetVanta ActivReach Quick Start Download Page 2](http://html1.mh-extra.com/html/adtran/netvanta-activreach/netvanta-activreach_quick-start_2854569002.webp)
Quick Start Guide, 61702595F17-13A, March 2015
Support - Phone: 888-423-8726, Email: [email protected]
Copyright © 2015 ADTRAN, Inc. All Rights Reserved.
Q
UICK
S
TART
NetVanta ActivReach Wall Plate Media Converter
P/N 1702595F17
I
NSTALLATION
I
NSTRUCTIONS
FOR
A
CTIV
R
EACH
E
THERNET
1.
Ensure that the NetVanta 1235P/1535P lines and any voice/POTS lines
are disconnected from the source prior to configuring and installing any
jacks inside the junction box.
2.
Configure the network cable on both the Media Converter end and the
NetVanta 1235P/1535P end in accordance with your installation
requirements for 1-pair or 4-pair operation as illustrated in
. Make sure both ends of the network cable
are configured in the same manner.
3.
Plug the RJ-45 connector of the configured cable into one of the
network ports of the NetVanta 1235P/1535P.
4.
Plug the configured junction box cable into the RJ-45 connector labeled
To Network
on the back of the Media Converter. After a few minutes,
the Media Converter power LED will light.
5.
Mount the Media Converter to junction box using the screws provided
(see the illustration on the first page).
6.
Insert a 10/100 Ethernet cable into the RJ-45 connector on the front
panel of the Media Converter labeled
To Device
.
7.
Insert the other end of the Ethernet cable into the downstream device.
I
NSTALLATION
I
NSTRUCTIONS
FOR
A
CTIV
R
EACH
E
THERNET
AND
O
PTIONAL
V
OICE
P
ASSTHROUGH
1.
Ensure that the NetVanta 1235P/1535P lines and any voice/POTS lines
are disconnected from the source prior to configuring and installing any
jacks inside the junction box.
2.
Configure the network cable on both the Media Converter end and the
NetVanta 1235P/1535P end in accordance with your installation
requirements 1-pair ActivReach and optional voice passthrough as
illustrated in
ActivReach Pin Connections on page 1
. Make sure both
ends of the network cable are configured in the same manner.
3.
Plug the RJ-45 connector of the configured cable into one of the
network ports of the NetVanta 1235P/1535P.
4.
Plug the RJ-11 connector of the configured cable into an RJ-11
connector on the PBX.
5.
On the Media Converter end, plug the configured cable’s RJ-45
connector into the connector on the Media Converter labeled To
Network and the RJ-11 connector in to the connector labeled POTS on
the back of the Media Converter. After a few minutes, the Media
Converter power LED will light.
6.
Mount the Media Converter to junction box using the screws provided
(see the illustration on the first page).
7.
Insert a 10/100 Ethernet cable into an appropriate connector on the
front panel of the Media Converter labeled
To Device
.
8.
Insert the other end of the Ethernet cable into the downstream device.
9.
Insert a phone cable into the RJ-11 connector on the bottom of the
Media Converter.
10. Insert the other end of the phone cable into the downstream POTS
phone.
NetVanta 1535P
25
26
27
28
VCID
PoE
LINK/ACT
EPS
RPS
STAT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
ActivReach
10/100Base-T
Downstream
PoE
Device
POTS
POTS
Phone
NetVanta 1535P
PBX Phone System
ActivReach
RJ-45
RJ-11
RJ-45
RJ-11
Wall
Plate
MC
Optional Voice Passthrough