ADTRAN NetVanta ActivReach Quick Start Download Page 2

Quick Start Guide, 61702595F17-13A, March 2015

Support - Phone: 888-423-8726, Email: [email protected]

Copyright © 2015 ADTRAN, Inc. All Rights Reserved.

Q

UICK

 S

TART

NetVanta ActivReach Wall Plate Media Converter

P/N 1702595F17

I

NSTALLATION

 I

NSTRUCTIONS

 

FOR

 A

CTIV

R

EACH

 E

THERNET

1.

Ensure that the NetVanta 1235P/1535P lines and any voice/POTS lines 
are disconnected from the source prior to configuring and installing any 
jacks inside the junction box.

2.

Configure the network cable on both the Media Converter end and the 
NetVanta 1235P/1535P end in accordance with your installation 
requirements for 1-pair or 4-pair operation as illustrated in 

ActivReach 

Pin Connections on page 1

. Make sure both ends of the network cable 

are configured in the same manner.

3.

Plug the RJ-45 connector of the configured cable into one of the 
network ports of the NetVanta 1235P/1535P.

4.

Plug the configured junction box cable into the RJ-45 connector labeled 

To Network

 on the back of the Media Converter. After a few minutes, 

the Media Converter power LED will light.

5.

Mount the Media Converter to junction box using the screws provided 
(see the illustration on the first page). 

6.

Insert a 10/100 Ethernet cable into the RJ-45 connector on the front 
panel of the Media Converter labeled 

To Device

7.

Insert the other end of the Ethernet cable into the downstream device.

I

NSTALLATION

 I

NSTRUCTIONS

 

FOR

 A

CTIV

R

EACH

 E

THERNET

AND

 O

PTIONAL

 V

OICE

 P

ASSTHROUGH

1.

Ensure that the NetVanta 1235P/1535P lines and any voice/POTS lines 
are disconnected from the source prior to configuring and installing any 
jacks inside the junction box.

2.

Configure the network cable on both the Media Converter end and the 
NetVanta 1235P/1535P end in accordance with your installation 
requirements 1-pair ActivReach and optional voice passthrough as 
illustrated in 

ActivReach Pin Connections on page 1

. Make sure both 

ends of the network cable are configured in the same manner.

3.

Plug the RJ-45 connector of the configured cable into one of the 
network ports of the NetVanta 1235P/1535P.

4.

Plug the RJ-11 connector of the configured cable into an RJ-11 
connector on the PBX.

5.

On the Media Converter end, plug the configured cable’s RJ-45 
connector into the connector on the Media Converter labeled To 
Network and the RJ-11 connector in to the connector labeled POTS on 
the back of the Media Converter. After a few minutes, the Media 
Converter power LED will light.

6.

Mount the Media Converter to junction box using the screws provided 
(see the illustration on the first page). 

7.

Insert a 10/100 Ethernet cable into an appropriate connector on the 
front panel of the Media Converter labeled 

To Device

8.

Insert the other end of the Ethernet cable into the downstream device.

9.

Insert a phone cable into the RJ-11 connector on the bottom of the 
Media Converter.

10. Insert the other end of the phone cable into the downstream POTS 

phone.

NetVanta 1535P

25

26

27

28

VCID

PoE

LINK/ACT

EPS

RPS

STAT

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

ActivReach

10/100Base-T

Downstream
PoE
Device

POTS

POTS
Phone

NetVanta 1535P

PBX Phone System

ActivReach

RJ-45

RJ-11

RJ-45

RJ-11

Wall

Plate

MC

Optional Voice Passthrough

Reviews: