ADTRAN NetVanta 1561i-04 Quick Start Manual Download Page 8

8

617111561F1-13A

Resetting the Switch

The RESET button can be used to reset the switch to a previous configuration, or to reset the switch to the factory defaults. To reset the switch, push and hold the 

RESET button for the length of time indicated in the table below. Once the switch has been reset successfully, the LEDs display the characteristics described below.

Troubleshooting the Switch

The following table provides basic troubleshooting steps for the NetVanta 1561i-04 switch when LED behavior indicates a problem.

Product Specifications

Electrical

■ Power Supply: 12 VDC to 48 VDC, 0.77 A to 0.24 A

Environment

■ Operating Temperature: -40°F to 167°F (-40°C to 75°C)
■ Storage Temperature: -40°F to 185°F (-40°C to 85°C)
■ Relative Humidity: 5 to 95 percent, non-condensing
■ Altitude: Less than 10000 feet (3000 meters)

Product Dimensions

■ Dimensions (W x H x D): 2.4-inch x 5.3-inch x 5.1-inch (62mm x 135mm x 130mm)
■ Weight: Less than 2.2 lbs. (Less than 1 Kg)
■ Mounting type: DIN rail/wall mount

SFP Ports (3 & 4)

Green

On

The port is enabled and a link to the connected device has been established with a speed of 1000 Mbps.

Blinking

The port is transmitting/receiving packets with a connection speed of 1000 Mbps.

Amber

On

The port is enabled and a link to the connected device has been established with a speed of 100 Mbps.

Blinking

The port is transmitting/receiving packets with a connection speed of 100 Mbps.

Off

The port has no active network cable connected, a link to a connected device has not been established, or 

the port is disabled.

Reset Task

RESET Button Hold Time

SYS LED Behavior

Port Status LED Behavior

Reset the switch to previous configuration

2 to 7 seconds

Blinking Green

All LED lights are OFF

Restore to Factory Default

7 to 12 seconds

Blinking Green

All LED lights stay ON

LED Behavior

Possible Cause 

Basic Troubleshooting Steps

The 

SYS

 LED is OFF The switch is not receiving 

power.

1. Verify that the correct power cord is connected firmly to the switch and to the DC outlet socket.

2. Unplug the power cord from the switch and then plug it back in to cycle the switch’s power.

3. If, after attempting Steps 1 and 2 the 

SYS

 LED is still OFF, plug the power cord into a different DC 

outlet socket to ensure the correct DC power source is being supplied to the switch.

The Port UP status 

LED is OFF

The port is not connected, or 

the connection is not working.

1. Verify that the cable connector plug is firmly inserted and locked into the port on both the switch and 

the connected device.

2. Verify that the connected device is up and running correctly.

3. If, after attempting Steps 1 and 2 the issue persists, try a different cable or a different port to 

determine whether the issue relates to the cable or a specific port.

4. Use the Web GUI to verify that the port is not disabled by configuration.

CAUTION!

f

Electrostatic Discharge (ESD) can damage electronic devices. When handling devices, wear an antistatic discharge wrist strap to prevent damage to 

electronic components. Place in antistatic packing material when transporting or storing. When installing or maintaining, always place devices on an 

approved antistatic mat that is electrically grounded.

CAUTION!

f

 

This product is intended for industrial locations. This equipment is intended to be installed and used only by instructed or skilled persons. This 

product is to be installed only in restricted access locations. Care should be taken to protect cables from damage or vandalism.

LED

Color

State

Description

Summary of Contents for NetVanta 1561i-04

Page 1: ...h on page 8 Product Specifications on page 8 Figure 1 NetVanta 1561i 04 Front Panel Layout WARNING f Read all warning cautions notes and installation instructions before installing or servicing this e...

Page 2: ...stomer Support For more information refer to the product warranty available online at https adtran wp_support_warranty Mounting the NetVanta 1561i 04 Switch on a DIN Rail Follow these instructions to...

Page 3: ...g the mounting bracket as a template mark the location on the wall to insert user provided screw anchors Screw anchors should be rated to support a minimum of 2 2 pounds 1 kg for the intended wall mou...

Page 4: ...I DO Relay Wires to the Switch The NetVanta 1561i 04 switch provides digital input and digital output signals using relay wires connected to the provided terminal block To install the DI DO terminal b...

Page 5: ...external device if one is connected The default state of the DO relay can be configured via software to be either opened or closed and when a user configured event is triggered the DO relay connectio...

Page 6: ...us of the PC is OK 5 Run your web browser on the PC enter either the DHCP assigned or factory default IP address to access the switch s web interface If your PC is configured correctly you will see th...

Page 7: ...e is not receiving power from Power1 On The device is powered ON correctly P2 Green Off The device is not receiving power from Power2 On The device is powered ON correctly LED Color State Description...

Page 8: ...iguration 2 to 7 seconds Blinking Green All LED lights are OFF Restore to Factory Default 7 to 12 seconds Blinking Green All LED lights stay ON LED Behavior Possible Cause Basic Troubleshooting Steps...

Page 9: ...ed by ADTRAN could void the user s authority to operate this equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Ru...

Reviews: