ADTRAN NetVanta 1560-08 Quick Start Manual Download Page 2

2

617101561F1-13A

Installing the Switch

Package Contents

■ NetVanta 1560-08 switch

■ AC power cord

■ DB-9 to RJ-45 cable

■ Micro-USB to USB cable

■ Four adhesive rubber feet

■ Quick Start.

Installation Overview

To install the switch, you will need to do the following:

1. Mount the switch
2. Connect AC Power
3. Install SFP Modules

Mounting the Switch in a 19-inch Rack

To mount the switch into a 19-inch rack, complete the following steps.

1. Attach the mounting brackets to both sides of the chassis. Insert the provided screws and tighten them with a screwdriver to secure the brackets.

Figure 3. Attaching Brackets to the Switch

2. Position the chassis in the stationary equipment rack. Allow 1-inch of clearance between units.

NOTE

g

Refer to the national, state and local electrical codes for the requirements for power, grounding, wiring, and installation methods.

CAUTION!

f

The NetVanta 1560-08 is intended for indoor use only. Ethernet cables and attached equipment are intended for use within the same building with 

equipotential bonding, and not intended to be placed in separate buildings or structures. Failure to deploy as described could result in permanent 

damage from lightning or other electrical events and voids the warranty.

WARNING!

f

This equipment is not suitable for use in locations where children are likely to be present.

NOTE

g

Rack mount brackets are NOT a default accessory with the unit; brackets can be ordered through ADTRAN, part number: 1700518F1.

Summary of Contents for NetVanta 1560-08

Page 1: ...n instructions before installing or servicing this equipment NetVanta 1560 08 SYSTEM CONSOLE USB RESET 1 2 3 4 5 6 7 8 9 10 9 10 RESET Button Port Status LEDs SYS LED CONSOLE Port 10 100 1000 RJ 45 Po...

Page 2: ...he chassis in the stationary equipment rack Allow 1 inch of clearance between units NOTE g Refer to the national state and local electrical codes for the requirements for power grounding wiring and in...

Page 3: ...ach the four adhesive rubber feet to the bottom of the switch Figure 5 Attaching the Rubber Feet Mounting the Switch on a Wall To mount the switch on a wall complete the following steps 1 Using the mo...

Page 4: ...be mounted in the face down orientation when wall mounted NOTE g The installation of this product must comply with the national state and local electrical code requirements as applicable The AC branc...

Page 5: ...h is connected to a DHCP server skip to Step 3 2 Reconfigure the PC s IP address and subnet mask as below so that it can communicate with the switch For example the method to change the PC s IP addres...

Page 6: ...e needed PC with VT100 terminal emulation software Micro USB to USB cable or a DB 9 to RJ45 Serial Cable the cables are provided along with the unit To initially configure the switch using the CLI com...

Page 7: ...ving packets and the connection speed is 1 Gbps Amber On The port is enabled has established a link to connected device and the connection speed is 100 Mbps Flashing The port is transmitting receiving...

Page 8: ...quipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAN ICES 003 A NMB 003 A CAUTION f This pr...