1
Section 61245207L2-5, Issue 2
61245207L2-5C
CONTENTS
1.
GENERAL .................................................................. 1
2.
INSTALLATION ....................................................... 2
3.
CONNECTIONS ........................................................ 6
4.
DSL SYSTEM TESTING .......................................... 6
5.
CONTROL PORT OPERATION .............................. 7
6.
DSL DEPLOYMENT GUIDELINES ...................... 13
7.
MAINTENANCE ..................................................... 14
8.
TROUBLESHOOTING PROCEDURES ................ 14
9.
PRODUCT SPECIFICATIONS ............................... 14
10.
WARRANTY AND CUSTOMER SERVICE ......... 14
Appendix A. FT1 Loopbacks ........................................ A-1
FIGURES
Figure 1.
ADTRAN FT1 DP for Nortel DE-4E Shelf ... 1
Figure 2.
P1 Switch Location ......................................... 5
Figure 3.
FT1 DP Edge Connector Wiring .................... 6
Figure 4.
Bantam Jack Arrangement .............................. 6
Figure 5.
RS-232 (DB-9) Pin Assignments .................... 7
Figure 6.
Introductory Menu Screen .............................. 8
Figure 7.
FT1 DP Main Menu Screen ............................ 8
Figure 8.
Current System Status Screen ......................... 9
Figure 9.
Performance History Screen ......................... 10
Figure 10. Loopback Options Screen ............................. 10
Figure 11. Self-Test Options Screen .............................. 11
Figure 12. Provisioning Options Screen ........................ 11
Figure 13. Troubleshooting Screen ................................ 12
Figure 14. DSL Deployment Guidelines ........................ 13
Figure A-1. FT1 Loopbacks .......................................... A-1
Figure A-2. FT1 DP Network Loopback ....................... A-1
Figure A-3. FT1 DP CPE Loopback ............................. A-1
Figure A-4. FT1 Repeater #1 or # 2 Network Loopback . A-2
Figure A-5. FNID Network Loopback .......................... A-2
Figure A-6. FNID CPE Loopback ................................. A-2
TABLES
Table 1.
Protected Loopback Mode Requirement ........ 2
Table 2.
SW1 Option Settings ....................................... 3
Table 3.
SW2 and SW3 Option Settings ....................... 4
Table 4.
Front Panel Indicators and Switches .............. 5
Table 5.
Definition of Screen Abbreviations ................ 7
Table 6.
Loop Insertion Loss Data .............................. 13
Table 7.
Troubleshooting Guide ................................. 14
Table 8.
FT1 DP Product Specifications .................... 15
Table A-1. FT1 Loopback Select Codes ...................... A-1
Section 61245207L2-5C
Issue 3, July 2000
CLEI Code # D4D31R8D _ _
FT1 DP
Fractional T1 Dataport For Nortel DE-4E Shelf
Installation and Maintenance
1. GENERAL
This practice serves as an Installation and
Maintenance guide for the ADTRAN Fractional T1
Dataport (FT1 DP). The ADTRAN FT1 DP
(P/N 1245207L2) is the Central Office (CO) unit used
to deploy a repeater-less FT1 circuit using 2-wire
metallic facilities. The unit occupies one slot in a
standard Nortel DE-4E (or equivalent) shelf.
Figure 1
is an illustration of the ADTRAN FT1 DP.
Revision History
This is the third release of this document.
Clarifications were made to the SW1 Option Settings.
Description
Signals are provided to and from the channel bank or
RT, while 2B1Q HDSL signals are provided to the
local loop.
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
Figure 1. ADTRAN FT1 DP for Nortel DE-4E Shelf
1245207L1
FT1 DP
SX
2
3
4
5
6 7
8 9
10
11
12
O
U
T
I
N
R
X
DSO
T
X
ALM
AP
DSL
DS1
LB
R
S
2
3
2
L
O
C
R
E
M